Evidence map›Paper›PMID 26302465›Full record

ArticlePloS one2015

Measurement of Thermal Effects of Doppler Ultrasound: An In Vitro Study.

Samir Helmy, Yvonne Bader, Marianne Koch, Denise Tiringer, Christian Kollmann

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Samir HelmyDepartment of Obstetrics and Gynecology, Medical University Vienna, Vienna, Austria.
Yvonne BaderDepartment of Gynecology, Obstetrics and Reproductive Medicine, University Clinic of Saarland, Homburg, Germany.
Marianne KochDepartment of Obstetrics and Gynecology, Medical University Vienna, Vienna, Austria; Karl Landsteiner Society, Austria.
Denise TiringerDepartment of Obstetrics and Gynecology, Medical University Vienna, Vienna, Austria.
Christian KollmannCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Medical University of Vienna · ATKarl Landsteiner Society · ATSaarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveUltrasound is considered a safe imaging modality and is routinely applied during early pregnancy. However, reservations are expressed concerning the application of Doppler ultrasound in early pregnancy due to energy emission of the ultrasound probe and its conversion to heat. The objective of this study was to evaluate the thermal effects of emitted Doppler ultrasound of different ultrasound machines and probes by means of temperature increase of in-vitro test-media.

methodsWe investigated the energy-output of 5 vaginal and abdominal probes of 3 ultrasound machines (GE Healthcare, Siemens, Aloka). Two in-vitro test objects were developed at the Center for Medical Physics and Biomedical Engineering, Medical University Vienna (water bath and hydrogel bath). Temperature increase during Doppler ultrasound emission was measured via thermal sensors, which were placed inside the test objects or on the probes' surface. Each probe was emitting for 5 minutes into the absorbing test object with 3 different TI/MI settings in Spectral Doppler mode.

resultsDuring water bath test, temperature increase varied between 0.1 and 1.0°C, depending on probe, setting and focus, and was found highest for spectral Doppler mode alone. Maximum temperature increase was found during the surface heating test, where values up to 2.4°C could be measured within 5 minutes of emission.

conclusionsActivation of Doppler ultrasound in the waterbath model causes a significant increase of temperature within one minute. Thermally induced effects on the embryo cannot be excluded when using Doppler ultrasound in early pregnancy.

Indexed as

TemperatureBody TemperatureFemaleFetusHumansPregnancyUltrasonography, DopplerUltrasonography, Prenatal

Identifiers

PMID26302465
PMCPMC4547707
OpenAlexW2273838059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.