Evidence map›Paper›PMID 26301868›Full record

ArticleMagnetic resonance in medicine2016

Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH.

Artem A Gorodetsky, Igor A Kirilyuk, Valery V Khramtsov, Denis A Komarov

Open access · bronzeAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
7.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 53 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Biomedical Applications of Graphene-Based Structures.Nanomaterials (Basel, Switzerland) · 2018
    Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Artem A GorodetskyVorozhtsov Institute of Organic Chemistry, Novosibirsk, Russia.
Igor A KirilyukVorozhtsov Institute of Organic Chemistry, Novosibirsk, Russia.
Valery V KhramtsovHeart & Lung Research Institute, Ohio State University, Columbus, Ohio, USA.
Denis A KomarovVorozhtsov Institute of Organic Chemistry, Novosibirsk, Russia.
Novosibirsk Institute of Organic Chemistry · RUNovosibirsk State University · RUWest Virginia University · US

Funding

West Virginia IDEA-CTRU54GM104942 · NIGMS · WEST VIRGINIA UNIVERSITY · PI Sally Lynn Hodder · 2012 to 2026
$81.0M
In vivo monitoring of tumor microenvironment regulation for macrophagesR01CA194013 · NCI · WEST VIRGINIA UNIVERSITY · PI Timothy D Eubank, Valery V Khramtsov · 2015 to 2026
$3.5M
Functional proton-electron double-resonance imaging: development and applicationR01EB014542 · NIBIB · OHIO STATE UNIVERSITY · PI KHRAMTSOV, VALERY V, SAMOUILOV, ALEXANDRE VALENTIN · 2012 to 2015
$1.3M
NCI NIH HHS R01 CA194013NIBIB NIH HHS R01 EB014542NIGMS NIH HHS U54 GM104942
6 · The paper itself

Abstract

purposeElectron paramagnetic resonance (EPR) imaging in the spectral-spatial domain with application of soluble paramagnetic probes provides an opportunity for spatially resolved functional measurements of living objects. The purpose of this study was to develop EPR methods for visualization of oxygenation and acidosis of ischemic myocardium.

methodsEPR oxygen measurements were performed using isotopically substituted (2) H,(15) N-dicarboxyproxyl. The radical has an EPR line width of 320 mG and oxygen-induced line broadening of 0.53 mG/mm Hg, providing oxygen sensitivity down to 5 μM. pH measurements were performed using previously developed pH-sensitive imidazoline nitroxide. The radical has an EPR spectrum with pH-dependable hyperfine splitting, pK = 6.6, providing pH sensitivity of approximately 0.05 U in the physiological range.

resultsEPR imaging of isolated and perfused rat hearts was performed in the two-dimensional + spectral domain. The spatial resolution of the measurements was about 1.4 mm. Marked tissue hypoxia was observed in the ischemic area of the heart after occlusion of the left anterior descending coronary artery. Tissue oxygenation was partly restored upon reperfusion. EPR mapping of myocardial pH indicated acidosis of the ischemic area down to pH 6.7-6.8.

conclusionThis study demonstrates the capability of low-field EPR and the nitroxide spin probes for mapping of myocardial oxygenation and pH. The developed approaches might be used for noninvasive investigation of microenvironment on living objects. Magn Reson Med 76:350-358, 2016. © 2015 Wiley Periodicals, Inc.

Indexed as

Hydrogen-Ion ConcentrationAlgorithmsAnimalsElectron Spin Resonance SpectroscopyHeart Function TestsMagnetic Resonance ImagingMolecular ImagingMyocardial IschemiaOximetryOxygenRatsRats, WistarReproducibility of ResultsSensitivity and SpecificityOxygenEPR imagingEPR oximetrymyocardial acidosismyocardial ischemianitroxide radicalsspin probes

Identifiers

PMID26301868
PMCPMC4766065
OpenAlexW2143955238

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.