Evidence map›Paper›PMID 26293388›Full record

ReviewApplied health economics and health policy2015

Vision Amniotic Leak Detector (ALD) to Eliminate Amniotic Fluid Leakage as a Cause of Vaginal Wetness in Pregnancy: A NICE Medical Technology Guidance.

A F Ray, S C Peirce, A R Wilkes, G Carolan-Rees

Open access · hybridAbstract readReview
In one paragraph

Review in Applied health economics and health policy, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

A F RayCedar, School of Engineering, Cardiff University, Cardiff, UK.
S C PeirceCedar, School of Engineering, Cardiff University, Cardiff, UK. peirces@cardiff.ac.uk.ORCID http://orcid.org/0000-0001-9102-1410
A R WilkesCedar, Cardiff and Vale University Health Board, Cardiff, UK.
G Carolan-ReesCedar, Cardiff and Vale University Health Board, Cardiff, UK.
Cardiff and Vale University Health Board · GBCardiff University · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In prelabour rupture of membranes (PROM) or preterm PROM the amniotic membranes rupture prior to labour. Where this is not overt a speculum examination is undertaken to confirm diagnosis. The Vision Amniotic Leak Detector (ALD) is a panty liner that can diagnose amniotic fluid as a cause of vaginal wetness. It was evaluated by the UK National Institute for Health and Care Excellence (NICE) as part of the Medical Technologies Evaluation Programme. The sponsor (CommonSense Ltd) identified five studies, of which three were deemed within scope by the External Assessment Centre (EAC). Two of these three used an inappropriate comparator. The EAC recalculated the diagnostic accuracy of Vision ALD using speculum examination as the comparator: sensitivity of 97% (95% CI 93-99%), negative predictive value of 96% (95% CI 92-98%). A negative result would therefore allow patients to be discharged with confidence. In the sponsor's cost-consequence model only patients with a positive Vision ALD result would have a speculum examination, producing a cost saving of around £10 per patient. The EAC felt that some costs were unjustified and the model did not include infection outcomes or use in a community setting. The EAC revised the sponsor's model and found the results were most sensitive to clinician costs. Vision ALD was associated with savings of around £15-£25 per patient when administration in lower-cost community healthcare avoided a referral to a higher-cost secondary-care centre. NICE published guidance MTG15 in July 2013 recommending that the case for adopting Vision ALD was supported by the evidence.

Indexed as

Amniotic FluidCost-Benefit AnalysisFemaleHealth Care CostsHumansPregnancyPremature Rupture of Fetal MembranesSensitivity and SpecificitySurgical InstrumentsVagina

Identifiers

PMID26293388
PMCPMC4575365
OpenAlexW1828702877

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390