Evidence map›Paper›PMID 26287202›Full record

ArticleSensors (Basel, Switzerland)2015

Designing a Microfluidic Device with Integrated Ratiometric Oxygen Sensors for the Long-Term Control and Monitoring of Chronic and Cyclic Hypoxia.

Samantha M Grist, Jonathan C Schmok, Meng-Chi Andy Liu, Lukas Chrostowski, Karen C Cheung

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. In vitro microfluidic models of tumor microenvironment to screen transport of drugs and nanoparticles.Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology · 2017
    Review
  12. Article
  13. Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Samantha M GristDepartment of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver V6T 1Z4, BC, Canada. sgrist@ece.ubc.ca.
Jonathan C SchmokDepartment of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver V6T 1Z4, BC, Canada. jonathan.schmok@alumni.ubc.ca.
Meng-Chi Andy LiuDepartment of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver V6T 1Z4, BC, Canada. andyliu@ece.ubc.ca.
Lukas ChrostowskiDepartment of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver V6T 1Z4, BC, Canada. lukasc@ece.ubc.ca.
Karen C CheungDepartment of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver V6T 1Z4, BC, Canada. kcheung@ece.ubc.ca.

Funding

Canadian Institutes of Health Research
6 · The paper itself

Abstract

Control of oxygen over cell cultures in vitro is a topic of considerable interest, as chronic and cyclic hypoxia can alter cell behaviour. Both static and transient hypoxic levels have been found to affect tumour cell behaviour; it is potentially valuable to include these effects in early, in vitro stages of drug screening. A barrier to their inclusion is that rates of transient hypoxia can be a few cycles/hour, which is difficult to reproduce in traditional in vitro cell culture environments due to long diffusion distances from control gases to the cells. We use a gas-permeable three-layer microfluidic device to achieve spatial and temporal oxygen control with biologically-relevant switching times. We measure the oxygen profiles with integrated, ratiometric optical oxygen sensors, demonstrate sensor and system stability over multi-day experiments, and characterize a pre-bleaching process to improve sensor stability. We show, with both finite-element modelling and experimental data, excellent control over the oxygen levels by the device, independent of fluid flow rate and oxygenation for the operating flow regime. We measure equilibration times of approximately 10 min, generate complex, time-varying oxygen profiles, and study the effects of oxygenated media flow rates on the measured oxygen levels. This device could form a useful tool for future long-term studies of cell behaviour under hypoxia.

Indexed as

AnimalsBiosensing TechniquesCalibrationCell HypoxiaCell LineComputer SimulationEquipment DesignFinite Element AnalysisHumansLimit of DetectionMicrofluidic Analytical TechniquesOxygenReproducibility of ResultsTime FactorsOxygenoptical oxygen sensorsspatiotemporal microfluidic oxygen controltransient/cyclic hypoxia

Identifiers

PMID26287202
PMCPMC4570408

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.