ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2016
Simultaneous reconstruction of attenuation and activity in cardiac PET can remove CT misalignment artifacts.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Feasibility of PET-enabled dual-energy CT imaging: First physical phantom and initial patient study results.European journal of nuclear medicine and molecular imaging · 2025Article
- A quantitative clinical evaluation of simultaneous reconstruction of attenuation and activity in time-of-flight PET.BMC medical imaging · 2023Article
- Application-specific nuclear medicalPhysics in medicine and biology · 2021Review
- PET-enabled dual-energy CT: image reconstruction and a proof-of-concept computer simulation study.Physics in medicine and biology · 2020Article
- Selection of PET Camera and Implications on the Reliability and Accuracy of Absolute Myocardial Blood Flow Quantification.Current cardiology reports · 2020Review
- Advances in imaging instrumentation for nuclear cardiology.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Review
- Time-of-flight in cardiac PET/TC: What do we know and what we should know?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2018Article
- The dream of imaging coronary artery inflammation with FDG PET/CT imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Updates on Stress Imaging Testing and Myocardial Viability With Advanced Imaging Modalities.Current treatment options in cardiovascular medicine · 2017Review
- Attenuation correction in emission tomography using the emission data--A review.Medical physics · 2016Article
Corrections and comments
- Commented on by
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMisalignment between positron emission tomography (PET) and computed tomography (CT) data is known to generate artifactual defects in cardiac PET images due to imprecise attenuation correction (AC). In this work, the use of a maximum likelihood attenuation and activity (MLAA) algorithm is proposed to avoid such artifacts in time-of-flight (TOF) PET.
methodsMLAA was implemented and tested using a thorax/heart phantom and retrospectively on fourteen (13)N-ammonia PET/CT perfusion studies. Global and local misalignments between PET and CT data were generated by shifting matched CT images or using CT data representative of the end-inspiration phase. PET images were reconstructed with MLAA and a 3D-ordered-subsets-expectation-maximization (OSEM)-TOF algorithm. Images obtained with 3D-OSEM-TOF and matched CT were used as references. These images were compared (qualitatively and semi-quantitatively) with those reconstructed with 3D-OSEM-TOF and MLAA for which a misaligned CT was used, respectively, for AC and initialization.
resultsPhantom experiment proved the capability of MLAA to converge toward the correct emission and attenuation distributions using, as input, only PET emission data, but convergence was very slow. Initializing MLAA with phantom CT images markedly improved convergence speed. In patient studies, when shifted or end-inspiration CT images were used for AC, 3D-OSEM-TOF reconstructions showed artifacts of increasing severity, size, and frequency with increasing mismatch. Such artifacts were absent in the corresponding MLAA images.
conclusionThe proposed implementation of the MLAA algorithm is a feasible and robust technique to avoid AC mismatch artifacts in cardiac PET studies provided that a CT of the source is available, even if poorly aligned.
Indexed as
Identifiers
26275447What OpenQuestion holds
Registered trials