Evidence map›Paper›PMID 26272460›Full record

ArticleInternational orthopaedics2016

Comparison of perpendicular to the coronal plane versus medial inclination for atlas pedicle screw insertion: an anatomic and radiological study in human cadavers.

Jun Ma, Jian Tang, Deguang Wang, Yucheng Zhu, Tao Sui, Xiaojian Cao

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Suggestion of a safe zone for C1 pedicle screws depending on anatomical peculiarities.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jun MaDepartment of Orthopedic, Affiliated Suqian Hospital of Xuzhou Medical College, Suqian, 223800, Jiangsu, China. majun87078@yeah.net.
Jian TangDepartment of Orthopedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, Jiangsu, China.
Deguang WangDepartment of Human Anatomy, Xuzhou Medical College, Xuzhou, 221004, Jiangsu, China.
Yucheng ZhuDepartment of Orthopedic, Affiliated Suqian Hospital of Xuzhou Medical College, Suqian, 223800, Jiangsu, China.
Tao SuiDepartment of Orthopedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, Jiangsu, China.
Xiaojian CaoDepartment of Orthopedics, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, Jiangsu, China. xiaojiancao001@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo ascertain the anatomic and radiological parameters of the atlas (C1) pedicle and to explore a preferable method of C1 pedicle screw insertion.

methodsThirty-four conserved human cadaveric cervical spines (20 males, 14 females) underwent computed tomography (CT) scanning. Trajectories P (perpendicular to the coronal plane) and I (with medial inclination) were designed for each C1 pedicle on CT images. External pedicle wall width, medullary cavity width, transverse angle, and optimal entry point along each trajectory were measured. Cortical screws of 3.5 mm in diameter were inserted into C1 pedicles along trajectory P and I, respectively, and wall perforation was assessed (post-operative CT scanning).

resultsThe external pedicle wall width and medullary cavity width along trajectory I were significantly wider than trajectory P (P < 0.01). Although external pedicle wall widths were all greater than 3.5 mm, medullary cavity width <3.5 mm was found in 16.1 % pedicles along trajectory P and only 2.9 % along trajectory I. Transverse angle was 21.8° along trajectory I and 0° along trajectory P. Optimal entry point of trajectory I was 4.1 mm lateral from that of trajectory P. The lateral wall perforation rate was significantly lower along trajectory I than trajectory P (P < 0.05).

conclusionsC1 pedicle screw trajectory with medial inclination and more lateral entry points yielded wider medullary cavity width than that perpendicular to the coronal plane, and might minimize lateral wall perforation.

Indexed as

Pedicle ScrewsAdultCadaverCervical AtlasFemaleHumansMaleTomography, X-Ray ComputedAtlasComputer tomographyPedicle screwTrajectory

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.