ArticleMagnetic resonance in medicine2016

Respiration artifact correction in three-dimensional proton resonance frequency MR thermometry using phase navigators.

Bryant T Svedin, Allison Payne, Dennis L Parker

Abstract readEvaluation Study
In one paragraph

Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Technical advances in motion-robust MR thermometry.Magnetic resonance in medicine · 2024
    Review
  2. Article
  3. Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023
    Article
  4. Article
  5. Phase-independent thermometry by Z-spectrum MR imaging.Magnetic resonance in medicine · 2022
    Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2016
    Article
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Bryant T SvedinUtah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
Allison PayneUtah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.
Dennis L ParkerUtah Center for Advanced Imaging Research, University of Utah, Salt Lake City, Utah, USA.

Funding

Non-Invasive MRI-Guided HIFU for Breast Cancer TherapyR01CA172787 · NCI · UNIVERSITY OF UTAH · PI PARKER, DENNIS L · 2013 to 2017
$2.7M
Improved MRI temperature imaging using a subject-specific biophysical modelR01EB013433 · NIBIB · UNIVERSITY OF UTAH · PI PARKER, DENNIS L · 2011 to 2014
$1.8M
NCI NIH HHS R01 CA172787NIBIB NIH HHS R01 EB013433
6 · The paper itself

Abstract

purposeTo develop reliable three-dimensional (3D) segmented echo planar imaging (seg-EPI) proton resonance frequency (PRF) temperature monitoring in the presence of respiration-induced B0 variation.

methodsA free induction decay (FID) phase navigator was inserted into a 3D seg-EPI sequence before and after EPI readout to monitor B0 field variations. Using the field change estimates, the phase of each k-space line was adjusted to remove the additional phase from the respiratory induced off-resonance. This correction technique was evaluated while heating with MR-guided focused ultrasound (MRgFUS) in phantoms with simulated breathing and during nonheating conditions in healthy in vivo breasts.

resultsWith k-space phase correction, the standard deviation of magnitude images and PRF temperature measurements in breast from five volunteers improved by an average factor of 1.5 and 2.1, respectively. Improved accuracy of temperature estimates was observed after correction while heating with MRgFUS in phantoms.

conclusionPhase correction based on two FID navigators placed before and after the echo train provides promising results for implementing 3D monitoring of thermal therapy treatments in the presence of field variations due to respiration. Magn Reson Med 76:206-213, 2016. © 2015 Wiley Periodicals, Inc.

Indexed as

ArtifactsAdultAlgorithmsBody TemperatureBreastEcho-Planar ImagingFemaleHumansImage EnhancementImage Interpretation, Computer-AssistedImaging, Three-DimensionalMiddle AgedProton Magnetic Resonance SpectroscopyReproducibility of ResultsRespiratory-Gated Imaging TechniquesRespiratory Mechanicsphase navigatorPRF temperaturerespiration correction

Identifiers

PMID26272108
PMCPMC4752934

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.