Evidence map›Paper›PMID 26270891›Full record

SynthesisThe Cochrane database of systematic reviews2015

Interventions for treating fractures of the distal femur in adults.

Xavier L Griffin, Nick Parsons, Mohamed M Zbaeda, John McArthur

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 2 pooled it
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 2 syntheses or guidelines pooled it, 62 citations in OpenAlex.

  1. Interventions for treating fractures of the distal femur in adults.The Cochrane database of systematic reviews · 2022
    Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Endosteal plating for the treatment of malunions and nonunions of distal femur fractures.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023
    Review
  13. Article
  14. The geriatric distal femur fracture: nail, plate or both?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023
    Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2021
    Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Xavier L GriffinWarwick Orthopaedics, Warwick Medical School, University of Warwick, Clinical Sciences Building, Clifford Bridge Road, Coventry, UK, CV2 2DX.
Nick Parsons
Mohamed M Zbaeda
John McArthur
University of Warwick · GBSt George's Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFractures of the distal femur (the part of the thigh bone nearest the knee) are a considerable cause of morbidity. Various different surgical and non-surgical treatments have been used in the management of these injuries but the best treatment remains controversial.

objectivesTo assess the effects (benefits and harms) of interventions for treating fractures of the distal femur in adults. SEARCH

methodsWe searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (9 September 2014); the Cochrane Central Register of Controlled Trials (The Cochrane Library, 2014, Issue 8); MEDLINE (1946 to August week 4 2014); EMBASE (1980 to 2014 week 36); World Health Organization (WHO) International Clinical Trials Registry Platform (January 2015); conference proceedings and reference lists without language restrictions. SELECTION CRITERIA: Randomised and quasi-randomised controlled clinical trials comparing interventions for treating fractures of the distal femur in adults. Our primary outcomes were patient-reported outcome measures (PROMs) of knee function and adverse events, including re-operations. DATA COLLECTION AND ANALYSIS: Two review authors independently selected studies and performed data extraction and risk of bias assessment. We assessed treatment effects using risk ratios (RR) or mean differences (MD) and, where appropriate, we pooled data using a fixed-effect model. MAIN

resultsWe included seven studies that involved a total of 444 adults with distal femur fractures. Each of the included studies was small and assessed to be at substantial risk of bias, with four studies being quasi-randomised and none of the studies using blinding in outcome assessment. All studies provided an incomplete picture of outcome. Based on GRADE criteria, we assessed the quality of the evidence as very low for all reported outcomes, which means we are very uncertain of the reliability of these results.One study compared surgical (dynamic condylar screw (DCS) fixation) and non-surgical (skeletal traction) treatment in 42 older adults (mean age 79 years) with displaced fractures of the distal femur. This study, which did not report on PROMs, provided very low quality evidence of little between-group differences in adverse events such as death (2/20 surgical versus 1/20 non-surgical), re-operation or repeat procedures (1/20 versus 3/20) and other adverse effects including delayed union. However, while none of the findings were statistically significant, there were more complications such as pressure sores (0/20 versus 4/20) associated with prolonged immobilisation in the non-surgical group, who stayed on average one month longer in hospital.The other six studies compared different surgical interventions. Three studies, including 159 participants, compared retrograde intramedullary nail (RIMN) fixation versus DCS or blade-plate fixation (fixed-angle devices). None of these studies reported PROMS relating to function. None of the results for the reported adverse events showed a difference between the two implants. Thus, although there was very low quality evidence of a higher risk of re-operation in the RIMN group, the 95% confidence interval (CI) also included the possibility of a higher risk of re-operation for the fixed-angle device (9/83 RIMN versus 4/96 fixed-angle device; 3 studies: RR 1.85, 95% CI 0.62 to 5.57). There was no clinically important difference between the two groups found in quality of life assessed using the 36-item Short Form in one study (23 fractures).One study (18 participants) provided very low quality evidence of there being little difference in adverse events between RIMN and non-locking plate fixation. One study (53 participants) provided very low quality evidence of a higher risk of re-operation after locking plate fixation compared with a single fixed-angle device (6/28 locking plate versus 1/25 fixed-angle device; RR 5.36, 95% CI 0.69 to 41.50); however, the 95% CI also included the possibility of a higher risk of re-operation for the fixed-angle device. Neither of these trials reported on PROMs.The largest included study, which reported outcomes in 126 participants at one-year follow-up, compared RIMN versus locking plate fixation; both implants are commonly used in current practice. None of the between-group differences in the reported outcomes were statistically significant; thus the CIs crossed the line of no effect. There was very low quality evidence of better patient-reported musculoskeletal function in the RIMN group based on Short Musculoskeletal Function Assessment (0 to 100: best function) scores (e.g. dysfunction index: MD -5.90 favouring RIMN, 95% CI -15.13 to 3.33) as well as quality of life using the EuroQoL-5D Index (0 to 1: best quality of life) (MD 0.10 favouring RIMN, 95% CI -0.01 to 0.21). The CIs for both results included a clinically important effect favouring RIMN but also a clinically insignificant effect in favour of locking plate fixation. AUTHORS'

conclusionsThis review highlights the major limitations of the available evidence concerning current treatment interventions for fractures of the distal femur. The currently available evidence is incomplete and insufficient to inform current clinical practice. Priority should be given to a definitive, pragmatic, multicentre randomised controlled clinical trial comparing contemporary treatments such as locked plates and intramedullary nails. At minimum, these should report validated patient-reported functional and quality-of-life outcomes at one and two years. All trials should be reported in full using the CONSORT guidelines.

Indexed as

AdultAgedFemaleFemoral FracturesFracture FixationHumansMaleMiddle AgedRandomized Controlled Trials as TopicTraction

Identifiers

PMID26270891
PMCPMC9207810
OpenAlexW1912194387

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.