SynthesisThe Cochrane database of systematic reviews2015
Silver-coated endotracheal tubes for prevention of ventilator-associated pneumonia in critically ill patients.
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 45 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
45 citing papers in PubMed, 3 syntheses or guidelines pooled it, 94 citations in OpenAlex.
- Pooled it
- [Ventilator-associated pneumonia (VAP) : A risk already at the time of anesthetic induction].Der Anaesthesist · 2017Pooled it
- Silver-coated endotracheal tubes for prevention of ventilator-associated pneumonia in critically ill patients.The Cochrane database of systematic reviews · 2015Pooled it
- Bacterial Colonization of Silver-Additive Ventilator Circuit in Patients Receiving Mechanical Ventilation: A Randomized Controlled Trial.The clinical respiratory journal · 2025Trial
- Ventilator-Associated Pneumonia (VAP) Prevention Bundle: A Multicenter Cross-Sectional Saudi Study to Assess Knowledge, Adherence, and Perceived Barriers Among ICU Practitioners in Hail Region.Pathogens (Basel, Switzerland) · 2026Article
- Are arms-based methods required to test the stable unit treatment value assumption (SUTVA) among Cochrane reviews of contagious infection prevention interventions?Global epidemiology · 2026Article
- Ceragenin-Coated Endotracheal Tubes for the Reduction of Ventilator-Associated Pneumonia: A Prospective, Longitudinal, Crossover, Interrupted Time, Implementation Study (CEASE VAP Study).Critical care explorations · 2026Article
- Arms-Based Meta-Analysis of Microbiological Endpoints of 88 VAP Prevention Studies Using Antimicrobial Versus Non-Antimicrobial Strategies-Towards 'VAP-Zero'?Antibiotics (Basel, Switzerland) · 2026Article
- Antimicrobial-coated endotracheal tubes: A narrative review.Journal of critical care · 2026Review
- Novel ten second antimicrobial coating for endotracheal tubes to prevent ventilator associated pneumonia.Scientific reports · 2026Article
- Systematic reviews and the Journal of Antimicrobial Chemotherapy; past, present and future. A systematic reappraisal.The Journal of antimicrobial chemotherapy · 2025Article
- Estimating the herd effects of antimicrobial prevention interventions on ventilator-associated pneumonia within ICU populations: a cluster randomized trial emulation using data from Cochrane reviews.The Journal of antimicrobial chemotherapy · 2025Article
- Current Approaches on Nurse-Performed Interventions to Prevent Healthcare-Acquired Infections: An Umbrella Review.Microorganisms · 2025Review
- Visualizing and diagnosing spillover within randomized concurrent controlled trials through the application of diagnostic test assessment methods.BMC medical research methodology · 2024Article
- A new model of endotracheal tube biofilm identifies combinations of matrix-degrading enzymes and antimicrobials able to eradicate biofilms of pathogens that cause ventilator-associated pneumonia.Microbiology (Reading, England) · 2024Article
- Rebound Inverts theAntibiotics (Basel, Switzerland) · 2024Article
- Increased ventilator utilization, ventilator-associated pneumonia, and mortality in non-COVID patients during the pandemic.Proceedings (Baylor University. Medical Center) · 2024Article
- Incidence of Airway Complications in ICU.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2023Article
- Review
- Effect of continuous local dexamethasone on tissue biomechanics and histology after inhalational burn in a preclinical model.Laryngoscope investigative otolaryngology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundVentilator-associated pneumonia (VAP) is one of the most common nosocomial infections in intubated and mechanically ventilated patients. Endotracheal tubes (ETTs) appear to be an independent risk factor for VAP. Silver-coated ETTs slowly release silver cations. It is these silver ions that appear to have a strong antimicrobial effect. Because of this antimicrobial effect of silver, silver-coated ETTs could be an effective intervention to prevent VAP in people who require mechanical ventilation for 24 hours or longer.
objectivesOur primary objective was to investigate whether silver-coated ETTs are effective in reducing the risk of VAP and hospital mortality in comparison with standard non-coated ETTs in people who require mechanical ventilation for 24 hours or longer. Our secondary objective was to ascertain whether silver-coated ETTs are effective in reducing the following clinical outcomes: device-related adverse events, duration of intubation, length of hospital and intensive care unit (ICU) stay, costs, and time to VAP onset. SEARCH
methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2014 Issue 10, MEDLINE, EMBASE, EBSCO CINAHL, and reference lists of trials. We contacted corresponding authors for additional information and unpublished studies. We did not impose any restrictions on the basis of date of publication or language. The date of the last search was October 2014. SELECTION CRITERIA: We included all randomized controlled trials (RCTs) and quasi-randomized trials that evaluated the effects of silver-coated ETTs or a combination of silver with any antimicrobial-coated ETTs with standard non-coated ETTs or with other antimicrobial-coated ETTs in critically ill people who required mechanical ventilation for 24 hours or longer. We also included studies that evaluated the cost-effectiveness of silver-coated ETTs or a combination of silver with any antimicrobial-coated ETTs. DATA COLLECTION AND ANALYSIS: Two review authors (GT, HV) independently extracted the data and summarized study details from all included studies using the specially designed data extraction form. We used standard methodological procedures expected by The Cochrane Collaboration. We performed meta-analysis for outcomes when possible. MAIN
resultsWe found three eligible randomized controlled trials, with a total of 2081 participants. One of the three included studies did not mention the amount of participants and presented no outcome data. The 'Risk of bias' assessment indicated that there was a high risk of detection bias owing to lack of blinding of outcomes assessors, but we assessed all other domains to be at low risk of bias. Trial design and conduct were generally adequate, with the most common areas of weakness in blinding. The majority of participants were included in centres across North America. The mean age of participants ranged from 61 to 64 years, and the mean duration of intubation was between 3.2 and 7.7 days. One trial comparing silver-coated ETTs versus non-coated ETTs showed a statistically significant decrease in VAP in favour of the silver-coated ETT (1 RCT, 1509 participants; 4.8% versus 7.5%, risk ratio (RR) 0.64, 95% confidence interval (CI) 0.43 to 0.96; number needed to treat for an additional beneficial outcome (NNTB) = 37; low-quality evidence). The risk of VAP within 10 days of intubation was significantly lower with the silver-coated ETTs compared with non-coated ETTs (1 RCT, 1509 participants; 3.5% versus 6.7%, RR 0.51, 95% CI 0.31 to 0.82; NNTB = 32; low-quality evidence). Silver-coated ETT was associated with delayed time to VAP occurrence compared with non-coated ETT (1 RCT, 1509 participants; hazard ratio 0.55, 95% CI 0.37 to 0.84). The confidence intervals for the results of the following outcomes did not exclude potentially important differences with either treatment. There were no statistically significant differences between groups in hospital mortality (1 RCT, 1509 participants; 30.4% versus 26.6%, RR 1.09, 95% CI 0.93 to 1.29; low-quality evidence); device-related adverse events (2 RCTs, 2081 participants; RR 0.65, 95% CI 0.37 to 1.16; low-quality evidence); duration of intubation; and length of hospital and ICU stay. We found no clinical studies evaluating the cost-effectiveness of silver-coated ETTs. AUTHORS'
conclusionsThis review provides limited evidence that silver-coated ETT reduces the risk of VAP, especially during the first 10 days of mechanical ventilation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.