Evidence map›Paper›PMID 26265403›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2015

Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis.

M G M Schotanus, E H van Haaren, R P M Hendrickx, E J P Jansen, N P Kort

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 11 citations in OpenAlex.

  1. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018
    Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

M G M SchotanusMedical Researcher at Zuyderland Medical Centre, Dr H vd Hoffplein 1, 6162 AG, Sittard-Geleen, The Netherlands. m.schotanus@orbisconcern.nl.
E H van HaarenOrthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. em.vanhaaren@orbisconcern.nl.
R P M HendrickxOrthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. r.hendrickx@orbisconcern.nl.
E J P JansenOrthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. ed.jansen@orbisconcern.nl.
N P KortOrthopedic Surgeon at Zuyderland Medical Centre, Sittard-Geleen, The Netherlands. n.kort@orbisconcern.nl.
Zuyderland Medisch Centrum · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Published clinical trials who studied the accuracy of patient-specific guides (PSG) for total knee arthroplasty exclude patients with articular deformity of the knee joint. We prospectively analysed a series of 30 patients with post-traumatic osteoarthritis of the knee joint with use of PSG. At 1 year post-operative, the achieved biomechanical (HKA) axis and varus/valgus of the femur and tibia components were measured on anterior-posterior (AP) long-standing weight-bearing radiographs. Flexion/extension of the femoral and AP slope of the tibia component was measured on standard lateral radiographs. Percentages >3° deviation of the pre-operative planned HKA axis and individual implant components were considered as outliers. Approved and used implant size, median blood loss (ml) and operation time (min) were obtained from the operation records. Pre- and 1-year post-operative patient-reported outcome measures (PROMs) were performed. Eighty-three per cent of the patients had a HKA axis restored <3° of the pre-operative planned alignment. Varus/valgus outliers were 0.0 and 6.7 % for the femoral and tibial components, respectively. Percentages of outliers of flexion/extension were 36.7 % for the femoral component and 10.0 % for the AP slope of the tibial component. Median blood loss was 300 ml (50-700), while operation time was 67 min (44-144). In 20 % of all cases, the approved implant size was changed into one size smaller. One-year post-operative PROMs improved significantly. We conclude that the accuracy of CT-based PSG is not impaired in patients with post-traumatic osteoarthritis and this modality can restore biomechanical limb alignment.

Indexed as

AgedArthroplasty, Replacement, KneeBlood Loss, SurgicalFemaleFracture Fixation, IntramedullaryHumansKnee InjuriesKnee ProsthesisMaleMiddle AgedOperative TimeOsteoarthritis, KneePatient Outcome AssessmentPreoperative CareProspective StudiesRadiography, InterventionalCT-basedKnee alignmentPatient-specific guidesPost-traumatic osteoarthritisRetained metal hardwareTotal knee arthroplasty

Identifiers

PMID26265403
OpenAlexW1176892759

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.