Evidence map›Paper›PMID 26261992›Full record

ArticlePloS one2015

Prothrombin Time and Activated Partial Thromboplastin Time Testing: A Comparative Effectiveness Study in a Million-Patient Sample.

Manu N Capoor, Jerry L Stonemetz, John C Baird, Fahad S Ahmed, Ahsan Awan, Christof Birkenmaier, Mario A Inchiosa, Steven K Magid, Kathryn McGoldrick, Ernesto Molmenti and 8 more

Open access · goldAbstract readMulticenter Study
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
6.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 35 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. An illustrated review of bleeding assessment tools and common coagulation tests.Research and practice in thrombosis and haemostasis · 2020
    Article
  8. Article
  9. Article
  10. Retrospective comparison of standard clotting tests and novel clot waveform parameters in dogs using the turbidimetric ACL-TOP CTS 300 coagulation analyzer.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2018
    Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors at 9 institutions in 2 countries.

Manu N CapoorDepartment of Bacterial Pathogenesis and Immunology, Rockefeller University, New York, New York, United States of America; MMF Systems, Inc., New York, New York, United States of America.
Jerry L StonemetzDepartment of Anesthesia, The Johns Hopkins Hospital, Baltimore, Maryland, United States of America.
John C BairdMMF Systems, Inc., New York, New York, United States of America.
Fahad S AhmedMMF Systems, Inc., New York, New York, United States of America.
Ahsan AwanDepartment of Anesthesia, Englewood Hospital and Medical Center, Englewood, New Jersey, United States of America.
Christof BirkenmaierLudwig-Maximilian University of Munich, Munich, Germany.
Mario A InchiosaWestchester Medical Center/New York Medical College, Valhalla, New York, United States of America.
Steven K MagidHospital for Special Surgery, New York, New York, United States of America.
Kathryn McGoldrickWestchester Medical Center/New York Medical College, Valhalla, New York, United States of America.
Ernesto MolmentiDepartment of Surgery, North Shore University Hospital, Manhasset, New York, United States of America.
Sajjad NaqviDepartment of Anesthesia, Englewood Hospital and Medical Center, Englewood, New Jersey, United States of America.
Stephen D ParkerDepartment of Anesthesia, Washington Hospital Center, Washington, DC, United States of America.
S M PothulaWestchester Medical Center/New York Medical College, Valhalla, New York, United States of America.
Aryeh ShanderDepartment of Anesthesia, Englewood Hospital and Medical Center, Englewood, New Jersey, United States of America.
R Grant SteenMMF Systems, Inc., New York, New York, United States of America.
Michael K UrbanHospital for Special Surgery, New York, New York, United States of America.
Judith WallAtlantic Health System, Morristown, New Jersey, United States of America.
Vincent A FischettiDepartment of Bacterial Pathogenesis and Immunology, Rockefeller University, New York, New York, United States of America.
Englewood Hospital and Medical Center · USWestchester Medical Center · USHospital for Special Surgery · USRockefeller University · USAtlantic Health System · USJohns Hopkins Hospital · USLudwig-Maximilians-Universität München · DEMedStar Washington Hospital Center · USNorth Shore University Hospital · US

Funding

Transforming Translational Science and Education to Benefit Human HealthUL1TR000043 · NCATS · ROCKEFELLER UNIVERSITY · PI COLLER, BARRY · 2012 to 2015
$26.8M
NCATS NIH HHS UL1 TR000043
6 · The paper itself

Abstract

backgroundA substantial fraction of all American healthcare expenditures are potentially wasted, and practices that are not evidence-based could contribute to such waste. We sought to characterize whether Prothrombin Time (PT) and activated Partial Thromboplastin Time (aPTT) tests of preoperative patients are used in a way unsupported by evidence and potentially wasteful. METHODS AND

findingsWe evaluated prospectively-collected patient data from 19 major teaching hospitals and 8 hospital-affiliated surgical centers in 7 states (Delaware, Florida, Maryland, Massachusetts, New Jersey, New York, Pennsylvania) and the District of Columbia. A total of 1,053,472 consecutive patients represented every patient admitted for elective surgery from 2009 to 2012 at all 27 settings. A subset of 682,049 patients (64.7%) had one or both tests done and history and physical (H&P) records available for analysis. Unnecessary tests for bleeding risk were defined as: PT tests done on patients with no history of abnormal bleeding, warfarin therapy, vitamin K-dependent clotting factor deficiency, or liver disease; or aPTT tests done on patients with no history of heparin treatment, hemophilia, lupus anticoagulant antibodies, or von Willebrand disease. We assessed the proportion of patients who received PT or aPTT tests who lacked evidence-based reasons for testing.

conclusionsThis study sought to bring the availability of big data together with applied comparative effectiveness research. Among preoperative patients, 26.2% received PT tests, and 94.3% of tests were unnecessary, given the absence of findings on H&P. Similarly, 23.3% of preoperative patients received aPTT tests, of which 99.9% were unnecessary. Among patients with no H&P findings suggestive of bleeding risk, 6.6% of PT tests and 7.1% of aPTT tests were either a false positive or a true positive (i.e. indicative of a previously-undiagnosed potential bleeding risk). Both PT and aPTT, designed as diagnostic tests, are apparently used as screening tests. Use of unnecessary screening tests raises concerns for the costs of such testing and the consequences of false positive results.

Indexed as

Partial Thromboplastin TimeProthrombin TimeAdultAgedEvidence-Based PracticeFemaleHospitals, TeachingHumansMaleMiddle AgedPreoperative CareUnited StatesUnnecessary ProceduresYoung Adult

Identifiers

PMID26261992
PMCPMC4532488
OpenAlexW2151045623

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.