Effects of magnetic resonance-guided high-intensity focused ultrasound ablation on bone mechanical properties and modeling.

Sin Yuin Yeo, Andrés J Arias Moreno, Bert van Rietbergen, Natalie D Ter Hoeve, Paul J van Diest, Holger Grüll

Open access · hybridAbstract read
In one paragraph

Article in Journal of therapeutic ultrasound, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Sin Yuin YeoDepartment of Biomedical Engineering, Eindhoven University of Technology, High Tech Campus 11-p1.243, 5656 AE Eindhoven, The Netherlands.
Andrés J Arias MorenoDepartment of Biomedical Engineering, Eindhoven University of Technology, High Tech Campus 11-p1.243, 5656 AE Eindhoven, The Netherlands.
Bert van RietbergenDepartment of Biomedical Engineering, Eindhoven University of Technology, High Tech Campus 11-p1.243, 5656 AE Eindhoven, The Netherlands.
Natalie D Ter HoeveDepartment of Pathology, University Medical Center Utrecht, Room H04.312, Utrecht, The Netherlands.
Paul J van DiestDepartment of Pathology, University Medical Center Utrecht, Room H04.312, Utrecht, The Netherlands.
Holger GrüllDepartment of Biomedical Engineering, Eindhoven University of Technology, High Tech Campus 11-p1.243, 5656 AE Eindhoven, The Netherlands ; Philips Research Europe, High Tech Campus 11-p1.261A, 5656 AE Eindhoven, The Netherlands.
Eindhoven University of Technology · NLUniversity Medical Center Utrecht · NLPhilips (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMagnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for palliative treatment of bone pain. In this study, the effects of MR-HIFU ablation on bone mechanics and modeling were investigated.

methodsA total of 12 healthy rat femurs were ablated using 10 W for 46 ± 4 s per sonication with 4 sonications for each femur. At 7 days after treatments, all animals underwent MR and single photon emission computed tomography/computed tomography (SPECT/CT) imaging. Then, six animals were euthanized. At 1 month following ablations, the remaining six animals were scanned again with MR and SPECT/CT prior to euthanization. Thereafter, both the HIFU-treated and contralateral control bones of three animals from each time interval were processed for histology, whereas the remaining bones were subjected to micro-CT (μCT), three-point bending tests, and micro-finite element (micro-FE) analyses.

resultsAt 7 days after HIFU ablations, edema formation around the treated bones coupled with bone marrow and cortical bone necrosis was observed on MRI and histological images. SPECT/CT and μCT images revealed presence of bone modeling through an increased uptake of (99m)Tc-MDP and formation of woven bone, respectively. At 31 days after ablations, as illustrated by imaging and histology, healing of the treated bone and the surrounding soft tissue was noted, marked by decreased in amount of tissue damage, formation of scar tissue, and sub-periosteal reaction. The results of three-point bending tests showed no significant differences in elastic stiffness, ultimate load, and yield load between the HIFU-treated and contralateral control bones at 7 days and 1 month after treatments. Similarly, the elastic stiffness and Young's moduli determined by micro-FE analyses at both time intervals were not statistically different.

conclusionsMultimodality imaging and histological data illustrated the presence of HIFU-induced bone damage at the cellular level, which activated the bone repair mechanisms. Despite that, these changes did not have a mechanical impact on the bone.

Indexed as

AblationBoneBone mechanical propertiesFocused ultrasoundHIFU

Identifiers

PMID26261720
PMCPMC4530487
OpenAlexW1735666496

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.