ArticleJournal of ultrasound2015
The role of ultrasonography in the assessment of peri-prosthetic hip complications.
Article in Journal of ultrasound, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Evaluating key ultrasound findings and their correlations with hip joint aspiration and prosthetic joint infection diagnosis following total hip arthroplasty.Skeletal radiology · 2025Article
- Pre-aspiration outpatient ultrasound can accurately predict dry taps in prosthetic hips suspected of infection; a prospective study.Frontiers in surgery · 2024Article
- Frameworks of wavelength selection in diffuse reflectance spectroscopy for tissue differentiation in orthopedic surgery.Journal of biomedical optics · 2023Article
- Metal Artifact Reduction Sequences MRI: A Useful Reference for Preoperative Diagnosis and Debridement Planning of Periprosthetic Joint Infection.Journal of clinical medicine · 2022Article
- Usefulness of doppler techniques in the diagnosis of peripheral iatrogenic pseudoaneurysms secondary to minimally invasive interventional and surgical procedures: imaging findings and diagnostic performance study.Journal of ultrasound · 2020Article
- Diagnosis of peripheral bone and prosthetic joint infections: overview on the consensus documents by the EANM, EBJIS, and ESR (with ESCMID endorsement).European radiology · 2019Review
- Radiological Imaging Evaluation of the Failing Total Hip Replacement.Frontiers in surgery · 2019Review
- Rotator cuff calcific tendinopathy: from diagnosis to treatment.Acta bio-medica : Atenei Parmensis · 2018Review
- Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?La Radiologia medica · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTotal hip arthroplasty (THA) is a widespread option for treating hip osteoarthritis. Peri-prosthetic complications after THA represent a common event influencing patient outcome and costs. The purpose of this paper is to report the use of ultrasonography (US) to detect peri-prosthetic complications in symptomatic patients who underwent THA.
methodsWe retrospectively reviewed the records of patients with THA who underwent imaging evaluation between January 2009 and December 2012 at two different institutions. We evaluated the presence/absence of superficial and/or deep peri-prosthetic collections as well as the presence/absence of a cutaneous sinus tract. For patients who underwent both MRI and US, a concordance correlation analysis between US and MR findings was performed.
resultsIn the reference period, 532 symptomatic patients (mean age ± standard deviation 74 ± 12 years) underwent X-ray and MRI examinations for suspected peri-prosthetic complications. Among them, 111 (20.9 %) underwent also US. Overall, 108 patients underwent both US and MRI. US findings included 67 superficial collections, 48 subcutaneous fistulas, 74 deep peri-prosthetic collections. Twenty-four patients had solid, mass-like peri-prosthetic collections. In 11 patients, no peri-prosthetic complications were seen. MRI findings included 68 superficial collections, 49 subcutaneous fistulas, 79 deep peri-prosthetic collections. Twenty-four patients had solid, mass-like peri-prosthetic collections. In four patients, no peri-prosthetic complications were seen. Concordance analysis between US and MRI findings showed almost perfect agreement (k ≥ 0.89).
conclusionUS is an efficient and practical imaging modality to evaluate peri-prosthetic complications in patients with THA, being almost comparable to MRI in detecting and characterizing these complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.