Evidence map›Paper›PMID 26257458›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2015

Enzymatic Glucose Sensor Compensation for Variations in Ambient Oxygen Concentration.

Bradley B Collier, Michael J McShane

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Bradley B CollierDepartment of Biomedical Engineering, Texas A&M University, College Station, TX 77843.
Michael J McShaneDepartment of Biomedical Engineering, Texas A&M University, College Station, TX 77843 ; Department of Materials Science and Engineering Program, Texas A&M University, College Station, TX 77843.
Texas A&M University · US

Funding

Implantable multi-analyte sensors for the continuous monitoring of body chemistriR01EB016414 · NIBIB · PROFUSA, INC. · PI MCSHANE, MIKE, WISNIEWSKI, NATALIE ANN · 2012 to 2015
$4.9M
Long-term Luminescence-based Glucose MonitoringR43DK093139 · NIDDK · PROFUSA, INC. · PI WISNIEWSKI, NATALIE ANN · 2011 to 2013
$1.1M
NIBIB NIH HHS R01 EB016414NIDDK NIH HHS R43 DK093139
6 · The paper itself

Abstract

Due to the increasing prevalence of diabetes, research toward painless glucose sensing continues. Oxygen sensitive phosphors with glucose oxidase (GOx) can be used to determine glucose levels indirectly by monitoring oxygen consumption. This is an attractive combination because of its speed and specificity. Packaging these molecules together in "smart materials" for implantation will enable non-invasive glucose monitoring. As glucose levels increase, oxygen levels decrease; consequently, the luminescence intensity and lifetime of the phosphor increase. Although the response of the sensor is dependent on glucose concentration, the ambient oxygen concentration also plays a key role. This could lead to inaccurate glucose readings and increase the risk of hyper- or hypoglycemia. To mitigate this risk, the dependence of hydrogel glucose sensor response on oxygen levels was investigated and compensation methods explored. Sensors were calibrated at different oxygen concentrations using a single generic logistic equation, such that trends in oxygen-dependence were determined as varying parameters in the equation. Each parameter was found to be a function of oxygen concentration, such that the correct glucose calibration equation can be calculated if the oxygen level is known. Accuracy of compensation will be determined by developing an overall calibration, using both glucose and oxygen sensors in parallel, correcting for oxygen fluctuations in real time by intentionally varying oxygen, and calculating the error in actual and predicted glucose levels. While this method was developed for compensation of enzymatic glucose sensors, in principle it can also be implemented with other kinds of sensors utilizing oxidases.

Indexed as

enzymatic glucose sensorsluminescence lifetimeoxygen compensation

Identifiers

PMID26257458
PMCPMC4524553
OpenAlexW2026002495

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.