Evidence map›Paper›PMID 26244783›Full record

ArticlePloS one2015

Spatial and Temporal Control of Hyperthermia Using Real Time Ultrasonic Thermal Strain Imaging with Motion Compensation, Phantom Study.

Josquin Foiret, Katherine W Ferrara

Abstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Optimized Echo Decorrelation Imaging Feedback for Bulk Ultrasound Ablation Control.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2018
    Article
  4. Article
  5. Quantitative Ultrasound for Monitoring High-Intensity Focused Ultrasound Treatment In Vivo.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2016
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Josquin FoiretDepartment of Biomedical Engineering, University of California Davis, Davis, CA, United States of America.
Katherine W FerraraDepartment of Biomedical Engineering, University of California Davis, Davis, CA, United States of America.

Funding

Ultrasound Imaging and Local Drug Delivery in TumorsR01CA103828 · NCI · UNIVERSITY OF CALIFORNIA DAVIS · PI FERRARA, KATHERINE W · 2004 to 2013
$10.4M
Ultrasound imaging and enhanced therapeutic responseR01CA134659 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W · 2009 to 2017
$4.4M
Optimized ultrasound-enhanced immunotherapyR01CA199658 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W · 2015 to 2019
$2.5M
NCI NIH HHS NIHR01CA103828NCI NIH HHS NIHR01CA134659NCI NIH HHS NIHR01CA199658NCI NIH HHS R01 CA103828NCI NIH HHS R01 CA134659NCI NIH HHS R01 CA199658
6 · The paper itself

Abstract

Mild hyperthermia has been successfully employed to induce reversible physiological changes that can directly treat cancer and enhance local drug delivery. In this approach, temperature monitoring is essential to avoid undesirable biological effects that result from thermal damage. For thermal therapies, Magnetic Resonance Imaging (MRI) has been employed to control real-time Focused Ultrasound (FUS) therapies. However, combined ultrasound imaging and therapy systems offer the benefits of simple, low-cost devices that can be broadly applied. To facilitate such technology, ultrasound thermometry has potential to reliably monitor temperature. Control of mild hyperthermia was previously achieved using a proportional-integral-derivative (PID) controller based on thermocouple measurements. Despite accurate temporal control of heating, this method is limited by the single position at which the temperature is measured. Ultrasound thermometry techniques based on exploiting the thermal dependence of acoustic parameters (such as longitudinal velocity) can be extended to create thermal maps and allow an accurate monitoring of temperature with good spatial resolution. However, in vivo applications of this technique have not been fully developed due to the high sensitivity to tissue motion. Here, we propose a motion compensation method based on the acquisition of multiple reference frames prior to treatment. The technique was tested in the presence of 2-D and 3-D physiological-scale motion and was found to provide effective real-time temperature monitoring. PID control of mild hyperthermia in presence of motion was then tested with ultrasound thermometry as feedback and temperature was maintained within 0.3°C of the requested value.

Indexed as

AnimalsHumansHyperthermia, InducedMagnetic Resonance ImagingMotionPhantoms, ImagingReproducibility of ResultsThermometryUltrasonic Therapy

Identifiers

PMID26244783
PMCPMC4526517

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked