Evidence map›Paper›PMID 26239145›Full record

ArticleAnnals of intensive care2015

Testing the implementation of an electronic process-of-care checklist for use during morning medical rounds in a tertiary intensive care unit: a prospective before-after study.

Karena M Conroy, Doug Elliott, Anthony R Burrell

Abstract read
In one paragraph

Article in Annals of intensive care, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Karena M ConroyNSW Intensive Care Co-ordination and Monitoring Unit, Agency for Clinical Innovation, Chatswood, Australia, karena.conroy@health.nsw.gov.au.
Doug Elliott
Anthony R Burrell

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo improve the delivery of important care processes in the ICU, morning ward round checklists have been implemented in a number of intensive care units (ICUs) internationally. Good quality evidence supporting their use as clinical support tools is lacking. With increased use of technology in clinical settings, integration of such tools into current work practices can be a challenge and requires evaluation. Having completed preliminary work revealing variations in practice and evidence supporting the construct validity of a process-of-care checklist, the need to develop, test and further validate an e(lectronic)-checklist in an ICU was identified.

methodsA prospective, before-after study was conducted in a 19-bed general ICU within a tertiary hospital. Data collection occurred during baseline and intervention periods for 6 weeks each, with education and training conducted over a 4-week period prior to intervention. The e-checklist was used at baseline by ICU research nurses conducting post-ward round audits. During intervention, senior medical staff completed the e-checklist after patient assessments during the morning ward rounds, and research staff conducted post-ward round audits for validity testing (via concordance measurement). To examine changes in compliance over time, checklist-level data were analysed using generalised estimating equations that factored in confounding variables, and statistical process control charts were used to evaluate unit-level data. Established measures of concordance were used to evaluate e-checklist validity.

resultsCompliance with each care component improved significantly over time; the largest improvement was for pain management (42% increase; adjusted odds ratio = 23, p < 0.001), followed by glucose management (22% increase, p < 0.001) and head-of-bed elevation (19% increase, p < 0.001), both with odds ratios greater than 10. Most detected omissions were corrected by the following day. Control charts illustrated reduced variability in care compliance over time. There was good concordance between physician and auditor e-checklist responses; seven out of nine cares had kappa values above 0.8.

conclusionImprovements in the delivery of essential daily care processes were evidenced after the introduction of an e-checklist to the morning ward rounds in an ICU. High levels of agreement between physician and independent audit responses lend support to the validity of the e-checklist.

Identifiers

PMID26239145
PMCPMC4523566

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.