Article in Physics in medicine and biology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 26 citations in OpenAlex.
- Asymmetric scatter kernel estimation neural network for digital breast tomosynthesis.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Accurate volume image reconstruction for digital breast tomosynthesis with directional-gradient and pixel sparsity regularization.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Scatter correction for contrast-enhanced digital breast tomosynthesis with a dual-layer detector.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Deep-learning convolutional neural network-based scatter correction for contrast enhanced digital breast tomosynthesis in both cranio-caudal and mediolateral-oblique views.Journal of medical imaging (Bellingham, Wash.) · 2023Article
- Identifying factors that may influence the classification performance of radiomics models using contrast-enhanced mammography (CEM) images.Cancer imaging : the official publication of the International Cancer Imaging Society · 2022Article
- Artificial intelligence in radiotherapy: a technological review.Frontiers of medicine · 2020Review
- Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.Journal of applied clinical medical physics · 2019Article
- Phantom-based study exploring the effects of different scatter correction approaches on the reconstructed images generated by contrast-enhanced stationary digital breast tomosynthesis.Journal of medical imaging (Bellingham, Wash.) · 2018Article
- A model-based scatter artifacts correction for cone beam CT.Medical physics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
Contrast-enhanced dual energy digital breast tomosynthesis (CE-DE-DBT) is designed to image iodinated masses while suppressing breast anatomical background. Scatter is a problem, especially for high energy acquisition, in that it causes severe cupping artifact and iodine quantitation errors. We propose a patient specific scatter correction (SC) algorithm for CE-DE-DBT. The empirical algorithm works by interpolating scatter data outside the breast shadow into an estimate within the breast shadow. The interpolated estimate is further improved by operations that use an easily obtainable (from phantoms) table of scatter-to-primary-ratios (SPR)--a single SPR value for each breast thickness and acquisition angle. We validated our SC algorithm for two breast emulating phantoms by comparing SPR from our SC algorithm to that measured using a beam-passing pinhole array plate. The error in our SC computed SPR, averaged over acquisition angle and image location, was about 5%, with slightly worse errors for thicker phantoms. The SC projection data, reconstructed using OS-SART, showed a large degree of decupping. We also observed that SC removed the dependence of iodine quantitation on phantom thickness. We applied the SC algorithm to a CE-DE-mammographic patient image with a biopsy confirmed tumor at the breast periphery. In the image without SC, the contrast enhanced tumor was masked by the cupping artifact. With our SC, the tumor was easily visible. An interpolation-based SC was proposed by (Siewerdsen et al 2006 Med. Phys. 33 187-97) for cone-beam CT (CBCT), but our algorithm and application differ in several respects. Other relevant SC techniques include Monte-Carlo and convolution-based methods for CBCT, storage of a precomputed library of scatter maps for DBT, and patient acquisition with a beam-passing pinhole array for breast CT. Our SC algorithm can be accomplished in clinically acceptable times, requires no additional imaging hardware or extra patient dose and is easily transportable between sites.