Evidence map›Paper›PMID 26236780›Full record

ArticleAbdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.)2014

Information-Preserving Pseudo-Enhancement Correction for Non-Cathartic Low-Dose Dual-Energy CT Colonography.

Janne J Näppi, Rie Tachibana, Daniele Regge, Hiroyuki Yoshida

Abstract read
In one paragraph

Article in Abdominal imaging : computational and clinical applications : 6th International Workshop, ABDI 2014, held in conjunction with MICCAI 2014, Cambridge, MA, USA, September 14, 2014. ABDI (Workshop) (6th : 2014 : Cambridge, Mass.), 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Context-specific method for detection of soft-tissue lesions in non-cathartic low-dose dual-energy CT colonography.Proceedings of SPIE--the International Society for Optical Engineering · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Janne J Näppi3D Imaging Research, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, 25 New Chardon Street, Suite 400C, Boston, MA 02114, USA.
Rie TachibanaInstitute for Cancer Research and Treatment, Candiolo Str. Prov. 142, 10060 Turin, Italy.
Daniele Regge
Hiroyuki Yoshida

Funding

Computerized Detection of Polyps in CT ColonographyR01CA095279 · NCI · UNIVERSITY OF CHICAGO · PI YOSHIDA, HIROYUKI · 2003 to 2013
$3.3M
NA-MIC virtual colonoscopyR01CA131718 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI YOSHIDA, HIROYUKI · 2009 to 2012
$2.1M
Cloud-computer-aided diagnostic imaging decision support systemR01CA166816 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI YOSHIDA, HIROYUKI · 2012 to 2015
$1.9M
Early diagnosis of colon cancer with computer-aided multi-energy CT colonographyR03CA182107 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI NAPPI, JANNE JOHANNES · 2014 to 2015
$174k
NCI NIH HHS R01 CA095279NCI NIH HHS R01 CA131718NCI NIH HHS R01 CA166816NCI NIH HHS R03 CA182107
6 · The paper itself

Abstract

In CT colonography (CTC), orally administered positive-contrast fecal-tagging agents can cause artificial elevation of the observed radiodensity of adjacent soft tissue. Such pseudo-enhancement makes it challenging to differentiate polyps and folds reliably from tagged materials, and it is also present in dual-energy CTC (DE-CTC). We developed a method that corrects for pseudo-enhancement on DE-CTC images without distorting the dual-energy information contained in the data. A pilot study was performed to evaluate the effect of the method visually and quantitatively by use of clinical non-cathartic low-dose DE-CTC data from 10 patients including 13 polyps covered partially or completely by iodine-based fecal tagging. The results indicate that the proposed method can be used to reduce the pseudo-enhancement distortion of DE-CTC images without losing material-specific dual-energy information. The method has potential application in improving the accuracy of automated image-processing applications, such as computer-aided detection and virtual bowel cleansing in CTC.

Indexed as

CT colonographyDual-energy CTPseudo-enhancementVirtual colonoscopy

Identifiers

PMID26236780
PMCPMC4521593

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.