ArticleThe Review of scientific instruments2015

A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy.

C R Krebs, Ling Li, Alisa S Wolberg, Amy L Oldenburg

Open access · greenAbstract read
In one paragraph

Article in The Review of scientific instruments, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

C R KrebsDepartment of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA.
Ling LiDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA.
Alisa S WolbergDepartment of Pathology and Laboratory Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA.
Amy L OldenburgDepartment of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA.
University of North Carolina at Chapel Hill · US

Funding

Cellular Determinants of Fibrin Structure and StabilityR01HL094740 · NHLBI · UNIV OF NORTH CAROLINA CHAPEL HILL · PI WOLBERG, ALISA S. · 2009 to 2013
$1.6M
Developing Contrast-Enhanced Ultrasound of Thrombosis via SPIO-RL PlateletsR21HL119928 · NHLBI · UNIV OF NORTH CAROLINA CHAPEL HILL · PI OLDENBURG, AMY L · 2014 to 2015
$411k
Novel Device for Sensitive, Small Sample Volume Assessment of Clot ElasticityR21HL109832 · NHLBI · UNIV OF NORTH CAROLINA CHAPEL HILL · PI OLDENBURG, AMY L · 2011 to 2012
$371k
NHLBI NIH HHS 1R01HL094740NHLBI NIH HHS 1R21HL109832NHLBI NIH HHS 1R21HL119928NHLBI NIH HHS R01 HL094740NHLBI NIH HHS R21 HL109832NHLBI NIH HHS R21 HL119928
6 · The paper itself

Abstract

Abnormal blood clot stiffness is an important indicator of coagulation disorders arising from a variety of cardiovascular diseases and drug treatments. Here, we present a portable instrument for elastometry of microliter volume blood samples based upon the principle of resonant acoustic spectroscopy, where a sample of well-defined dimensions exhibits a fundamental longitudinal resonance mode proportional to the square root of the Young's modulus. In contrast to commercial thromboelastography, the resonant acoustic method offers improved repeatability and accuracy due to the high signal-to-noise ratio of the resonant vibration. We review the measurement principles and the design of a magnetically actuated microbead force transducer applying between 23 pN and 6.7 nN, providing a wide dynamic range of elastic moduli (3 Pa-27 kPa) appropriate for measurement of clot elastic modulus (CEM). An automated and portable device, the CEMport, is introduced and implemented using a 2 nm resolution displacement sensor with demonstrated accuracy and precision of 3% and 2%, respectively, of CEM in biogels. Importantly, the small strains (<0.13%) and low strain rates (<1/s) employed by the CEMport maintain a linear stress-to-strain relationship which provides a perturbative measurement of the Young's modulus. Measurements of blood plasma CEM versus heparin concentration show that CEMport is sensitive to heparin levels below 0.050 U/ml, which suggests future applications in sensing heparin levels of post-surgical cardiopulmonary bypass patients. The portability, high accuracy, and high precision of this device enable new clinical and animal studies for associating CEM with blood coagulation disorders, potentially leading to improved diagnostics and therapeutic monitoring.

Indexed as

AcousticsAnticoagulantsAutomation, LaboratoryBlood CoagulationBlood Coagulation TestsCalibrationCardiopulmonary BypassDose-Response Relationship, DrugElastic ModulusEquipment DesignHeparinHumansLinear ModelsMagnetsMicrospheresMicrotechnologyAnticoagulantsHeparin

Identifiers

PMID26233406
PMCPMC4506305
OpenAlexW1486449402

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.