ArticleMedical physics2015
Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.
Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Comparison of sequential multi-detector CT and cone-beam CT perfusion maps in 39 subjects with anterior circulation acute ischemic stroke due to a large vessel occlusion.Journal of medical imaging (Bellingham, Wash.) · 2024Article
- Turn-table micro-CT scanner for dynamic perfusion imaging in mice: design, implementation, and evaluation.Physics in medicine and biology · 2024Article
- Penalized maximum-likelihood reconstruction for improving limited-angle artifacts in a dedicated head and neck PET system.Physics in medicine and biology · 2020Article
- Design study of a dedicated head and neck cancer PET system.IEEE transactions on radiation and plasma medical sciences · 2020Article
- An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.IEEE transactions on medical imaging · 2020Article
- An Empirical Data Inconsistency Metric (DIM) Driven CT Image Reconstruction Method.IEEE transactions on medical imaging · 2019Article
- Photon-counting cine-cardiac CT in the mouse.PloS one · 2019Article
- Quantification of temporal resolution improvement factor in SMART-RECON based time-resolved C-arm Cone beam computed tomography angiography (TR-CBCTA).Physics in medicine and biology · 2018Article
- Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection.Physics in medicine and biology · 2018Article
- Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.Medical physics · 2018Article
- Cone-beam CT reconstruction for non-periodic organ motion using time-ordered chain graph model.Radiation oncology (London, England) · 2017Article
- A new CT reconstruction technique using adaptive deformation recovery and intensity correction (ADRIC).Medical physics · 2017Article
- Quantifying the Cerebral Hemodynamics of Dural Arteriovenous Fistula in Transverse Sigmoid Sinus Complicated by Sinus Stenosis: A Retrospective Cohort Study.AJNR. American journal of neuroradiology · 2017Article
- Improving radiation dose efficiency of X-ray differential phase contrast imaging using an energy-resolving grating interferometer and a novel rank constraint.Optics express · 2016Article
- Using Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics: A Pilot Feasibility Study in Patients With Carotid Stenosis.Medicine · 2016Article
- Reduction of Beam Hardening Artifacts in Cone-Beam CT Imaging via SMART-RECON Algorithm.Proceedings of SPIE--the International Society for Optical Engineering · 2016Article
- Mask free Intravenous 3D Digital Subtraction Angiography (IV 3D-DSA) from a single C-arm acquisition.Proceedings of SPIE--the International Society for Optical Engineering · 2016Article
- SmoothedBioMed research international · 2016Article
- C-arm cone beam CT perfusion imaging using the SMART-RECON algorithm to improve temporal sampling density and temporal resolution.Proceedings of SPIE--the International Society for Optical EngineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIn x-ray computed tomography (CT), a violation of the Tuy data sufficiency condition leads to limited-view artifacts. In some applications, it is desirable to use data corresponding to a narrow temporal window to reconstruct images with reduced temporal-average artifacts. However, the need to reduce temporal-average artifacts in practice may result in a violation of the Tuy condition and thus undesirable limited-view artifacts. In this paper, the authors present a new iterative reconstruction method, synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON), to eliminate limited-view artifacts using data acquired within an ultranarrow temporal window that severely violates the Tuy condition.
methodsIn time-resolved contrast enhanced CT acquisitions, image contrast dynamically changes during data acquisition. Each image reconstructed from data acquired in a given temporal window represents one time frame and can be denoted as an image vector. Conventionally, each individual time frame is reconstructed independently. In this paper, all image frames are grouped into a spatial-temporal image matrix and are reconstructed together. Rather than the spatial and/or temporal smoothing regularizers commonly used in iterative image reconstruction, the nuclear norm of the spatial-temporal image matrix is used in SMART-RECON to regularize the reconstruction of all image time frames. This regularizer exploits the low-dimensional structure of the spatial-temporal image matrix to mitigate limited-view artifacts when an ultranarrow temporal window is desired in some applications to reduce temporal-average artifacts. Both numerical simulations in two dimensional image slices with known ground truth and in vivo human subject data acquired in a contrast enhanced cone beam CT exam have been used to validate the proposed SMART-RECON algorithm and to demonstrate the initial performance of the algorithm. Reconstruction errors and temporal fidelity of the reconstructed images were quantified using the relative root mean square error (rRMSE) and the universal quality index (UQI) in numerical simulations. The performance of the SMART-RECON algorithm was compared with that of the prior image constrained compressed sensing (PICCS) reconstruction quantitatively in simulations and qualitatively in human subject exam.
resultsIn numerical simulations, the 240(∘) short scan angular span was divided into four consecutive 60(∘) angular subsectors. SMART-RECON enables four high temporal fidelity images without limited-view artifacts. The average rRMSE is 16% and UQIs are 0.96 and 0.95 for the two local regions of interest, respectively. In contrast, the corresponding average rRMSE and UQIs are 25%, 0.78, and 0.81, respectively, for the PICCS reconstruction. Note that only one filtered backprojection image can be reconstructed from the same data set with an average rRMSE and UQIs are 45%, 0.71, and 0.79, respectively, to benchmark reconstruction accuracies. For in vivo contrast enhanced cone beam CT data acquired from a short scan angular span of 200(∘), three 66(∘) angular subsectors were used in SMART-RECON. The results demonstrated clear contrast difference in three SMART-RECON reconstructed image volumes without limited-view artifacts. In contrast, for the same angular sectors, PICCS cannot reconstruct images without limited-view artifacts and with clear contrast difference in three reconstructed image volumes.
conclusionsIn time-resolved CT, the proposed SMART-RECON method provides a new method to eliminate limited-view artifacts using data acquired in an ultranarrow temporal window, which corresponds to approximately 60(∘) angular subsectors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.