ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2015
Field-stepped direct detection electron paramagnetic resonance.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 23 citations in OpenAlex.
- Magnetic, EPR, and Computational Insights into ∼D6h Tb(III) and Gd(III) Complexes.Inorganic chemistry · 2026Article
- Segmented-overlap Fourier filtering and averaging (SOFFA) approach to improve concentration sensitivity of magnetic resonance spectra.Magnetic resonance (Gottingen, Germany) · 2026Article
- Advances in rapid scan EPR spectroscopy.Methods in enzymology · 2022Article
- Rapid-scan electron paramagnetic resonance using an EPR-on-a-Chip sensor.Magnetic resonance (Gottingen, Germany) · 2021Article
- Electron paramagnetic resonance of lanthanides.Methods in enzymology · 2021Article
- EPR Everywhere.Applied magnetic resonance · 2021Review
- Rapid-Scan Electron Paramagnetic Resonance of Highly Resolved Hyperfine Lines in Organic Radicals.Chemphyschem : a European journal of chemical physics and physical chemistry · 2020Article
- Rapid Scan EPR imaging as a Tool for Magnetic Field Mapping.Applied magnetic resonance · 2020Article
- Electron Spin Relaxation of TbApplied magnetic resonance · 2020Article
- 250 MHz Rapid Scan Cross Loop Resonator.Applied magnetic resonance · 2019Article
- Background correction in rapid scan EPR spectroscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018Article
- Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Review
- Rapid-Scan EPR of Nitroxide Spin Labels and Semiquinones.Methods in enzymology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
The widest scan that had been demonstrated previously for rapid scan EPR was a 155G sinusoidal scan. As the scan width increases, the voltage requirement across the resonating capacitor and scan coils increases dramatically and the background signal induced by the rapidly changing field increases. An alternate approach is needed to achieve wider scans. A field-stepped direct detection EPR method that is based on rapid-scan technology is now reported, and scan widths up to 6200G have been demonstrated. A linear scan frequency of 5.12kHz was generated with the scan driver described previously. The field was stepped at intervals of 0.01 to 1G, depending on the linewidths in the spectra. At each field data for triangular scans with widths up to 11.5G were acquired. Data from the triangular scans were combined by matching DC offsets for overlapping regions of successive scans. This approach has the following advantages relative to CW, several of which are similar to the advantages of rapid scan. (i) In CW if the modulation amplitude is too large, the signal is broadened. In direct detection field modulation is not used. (ii) In CW the small modulation amplitude detects only a small fraction of the signal amplitude. In direct detection each scan detects a larger fraction of the signal, which improves the signal-to-noise ratio. (iii) If the scan rate is fast enough to cause rapid scan oscillations, the slow scan spectrum can be recovered by deconvolution after the combination of segments. (iv) The data are acquired with quadrature detection, which permits phase correction in the post processing. (v) In the direct detection method the signal typically is oversampled in the field direction. The number of points to be averaged, thereby improving the signal-to-noise ratio, is determined in post processing based on the desired field resolution. A degased lithium phthalocyanine sample was used to demonstrate that the linear deconvolution procedure can be employed with field-stepped direct detection EPR signals. Field-stepped direct detection EPR spectra were obtained for Cu(2+) doped in Ni(diethyldithiocarbamate)2, Cu(2+) doped in Zn tetratolylporphyrin, perdeuterated tempone in sucrose octaacetate, vanadyl ion doped in a parasubstituted Zn tetratolylporphyrin, Mn(2+) impurity in CaO, and an oriented crystal of Mn(2+) doped in Mg(acetylacetonate)2(H2O)2.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.