ArticlePloS one2015
Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.
Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Pooled it
- Pooled it
- Prognostic significance of non-perfusion parameters of cadmium-zinc-telluride single-photon emission computed tomography myocardial perfusion imaging for individuals with normal myocardial perfusion: a large-scale single-center retrospective cohort study.Annals of nuclear medicine · 2025Article
- Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- SPECT and PET in ischemic heart failure.Heart failure reviews · 2017Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeMyocardial perfusion imaging (MPI) using gated single-photon emission tomography (gSPECT) may underestimate the severity of coronary artery disease (CAD). This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD.
methodsA total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI) were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS); sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR) were calculated. Treadmill parameters, including ST depression (STD) at the 1st and 3rd minutes of recovery stage (1'STD and 3'STD), maximal STD corrected by heart rate increment (ST/HR), heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio), systolic and mean blood pressure ratios (SBP ratio and MAP ratio) during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC) analysis and logistic regression for detection of left main (≥ 50%) or 3-vessel disease (all ≥ 70% luminal stenosis) on invasive angiography.
resultsAmong various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS) and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm), respectively. By univariate logistic regression, all parameters except 1'HRR, 3'HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3'STD, and HR ratio remained significant after multivariate regression. The predicted values of combined MPI and treadmill parameters (LHR, 3'STD, and HR ratio) gave the best ROC (AUC: 0.91) than any individual parameter or parameter combination.
conclusionsOf all treadmill and gSPECT parameters, the combination of MPI and treadmill parameters can offer better diagnostic performance for severe CAD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials