Sudden loss of the deep brain stimulation effect with high impedance without macroscopic fracture: a case report and review of the published literature.

Hui-Jun Yang, Ji Young Yun, Young Eun Kim, Yong Hoon Lim, Han-Joon Kim, Sun Ha Paek, Beom S Jeon

Open access · goldAbstract read
In one paragraph

Article in Neuropsychiatric disease and treatment, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Pediatric Deep Brain Stimulation for Dystonia: Current State and Ethical Considerations.Cambridge quarterly of healthcare ethics : CQ : the international journal of healthcare ethics committees · 2020
    Article
  4. Management of Elevated Therapeutic Impedances on Deep Brain Stimulation Leads.Tremor and other hyperkinetic movements (New York, N.Y.) · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Hui-Jun YangDepartment of Neurology, Ulsan University Hospital, Ulsan, South Korea.
Ji Young YunDepartment of Neurology, Ewha Womans University Mokdong Hospital, Seoul, South Korea.
Young Eun KimDepartment of Neurology, Hallym University Sacred Heart Hospital, Anyang, South Korea.
Yong Hoon LimDepartment of Neurosurgery, Seoul National University Hospital, Seoul, South Korea.
Han-Joon KimDepartment of Neurology and Movement Disorder Center, Parkinson's Disease Study Group and Neuroscience Research Institute, Seoul National University Hospital, Seoul, South Korea.
Sun Ha PaekDepartment of Neurosurgery, Seoul National University Hospital, Seoul, South Korea.
Beom S JeonDepartment of Neurology and Movement Disorder Center, Parkinson's Disease Study Group and Neuroscience Research Institute, Seoul National University Hospital, Seoul, South Korea.
Seoul National University Hospital · KREwha Womans University · KRHallym University Sacred Heart Hospital · KRUlsan University Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The number of deep brain stimulation (DBS) hardware complications has increased during the past decade. In cases of abnormally high lead impedance with no evidence of a macroscopic fracture, optimal treatment options have not yet been established. Here, we present the case of a 49-year-old woman with a 12-year history of Parkinson's disease who received bilateral subthalamic nucleus DBS in March 2006. The patient showed good control of parkinsonism until December 24, 2010, when she awoke with abrupt worsening of parkinsonian symptoms. At telemetric testing, lead impedances were found at >2,000 Ω in all four leads on the left side. Fracture of a lead or an extension wire was suspected. However, radiological screening and palpation revealed no macroscopic fracture. In June 2011, the implantable pulse generator (IPG) was changed under local anesthesia without any complications. Postoperatively, her parkinsonism immediately improved to the previous level, and the lead impedance readings by telemetry were also normalized. The disconnection of the neurostimulator connector block and the hybrid circuit board of the IPG was confirmed by destructive analysis. The present report illustrates that a staged approach that starts with simple IPG replacement can be an option for some cases of acute DBS effect loss with high impedance, when radiological findings are normal, thereby sparing the intact electrodes and extension wires.

Indexed as

connector blockhardware complicationimplantable neurostimulatorsParkinson’s disease

Identifiers

PMID26229475
PMCPMC4516336
OpenAlexW1495733380

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.