Evidence map›Paper›PMID 26227533›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2015

First determination of the heart-to-mediastinum ratio using cardiac dual isotope (¹²³I-MIBG/⁹⁹mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study.

Dimitri Bellevre, Alain Manrique, Damien Legallois, Samy Bross, Rafael Baavour, Nathaniel Roth, Tanguy Blaire, Cédric Desmonts, Alban Bailliez, Denis Agostini

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02515812 (Comparative Study of Cardiac Adrenergic Function Explored by I-123-MIBG and CZT Camera), which is not on this map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
8.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02515812 nacompletednot on this map

Comparative Study of Cardiac Adrenergic Function Explored by I-123-MIBG and CZT Camera (D-SPECT) Versus Anger Camera in Patients With Heart Failure

TypeinterventionalSponsorUniversity Hospital, CaenRan2012Enrolled45ConditionsHeart FailureArmsI-123-MIBG, CZT Camera (D-SPECT), Anger Camera
3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 69 citations in OpenAlex.

  1. Article
  2. Nuclear medicine and molecular imaging · 2024
    Review
  3. Are nuclear medicine images quantified in 2D and 3D equally functional?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  4. Article
  5. Phantom-Based Standardization Method forAnnals of nuclear cardiology · 2023
    Article
  6. Review
  7. The utility of heart-to-mediastinum ratio using a planar image created from IQ-SPECT with Iodine-123 meta-iodobenzylguanidine.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  8. Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison withJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  9. Article
  10. Simultaneous dual-tracerJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  11. I-123-MIBG cardiac innervation imaging in patients with atrial fibrillation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  12. Article
  13. Article
  14. Simultaneous dual isotopeJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  15. Quantification of myocardialEJNMMI research · 2019
    Article
  16. Phase dyssynchrony andJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
  17. Article
  18. First assessment of simultaneous dual isotope (Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  19. Relationships between left ventricular sympathetic innervation and diastolic dysfunction: the role of myocardial innervation/perfusion mismatch.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  20. First validation of myocardial flow reserve assessed by dynamicEuropean journal of nuclear medicine and molecular imaging · 2018
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Dimitri BellevreDepartment of Nuclear Medicine, CHU Côte de Nacre, Caen, France.
Alain ManriqueDepartment of Nuclear Medicine, CHU Côte de Nacre, Caen, France.
Damien LegalloisEA 4650, Normandie Université, Caen, France.
Samy BrossSpectrum Dynamics, Biosensors, Caesarea, Israel.
Rafael BaavourSpectrum Dynamics, Biosensors, Caesarea, Israel.
Nathaniel RothSpectrum Dynamics, Biosensors, Caesarea, Israel.
Tanguy BlaireEA 4650, Normandie Université, Caen, France.
Cédric DesmontsDepartment of Nuclear Medicine, CHU Côte de Nacre, Caen, France.
Alban BailliezEA 4650, Normandie Université, Caen, France.
Denis AgostiniDepartment of Nuclear Medicine, CHU Côte de Nacre, Caen, France. agostini-de@chu-caen.fr.
Centre Hospitalier Universitaire de Caen · FRNormandie Université · FRGouvernance, Risque, Environnement, Développement · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCardiac innervation is assessed using the heart-to-mediastinum ratio (HMR) of metaiodobenzylguanidine (MIBG) on planar imaging using Anger single photon emission computed tomography (A-SPECT). The aim of the study was to determine the HMR of MIBG obtained using a CZT-based camera (D-SPECT; Spectrum Dynamics, Israel) in comparison with that obtained using conventional planar imaging.

methodsThe ADRECARD study prospectively evaluated 44 patients with heart failure. They underwent planar acquisition using the A-SPECT camera 4 h after (123)I-MIBG injection (236.4 ± 39.7 MBq). To localize the heart using D-SPECT, (99m)Tc-tetrofosmin (753 ± 133 MBq) was administered and dual isotope acquisition was performed using the D-SPECT system. HMR was calculated using both planar A-SPECT imaging and front view D-SPECT cine data. In a phantom study, we estimated a model fitting the A-SPECT and the D-SPECT data that was further applied to correct for differences between the cameras.

resultsA total of 44 patients (39 men and 5 women, aged 60 ± 11 years) with ischaemic (31 patients) and nonischaemic (13 patients) cardiomyopathy completed the study. Most patients (28 of 44) were NYHA class II, and the mean left ventricular ejection fraction was 33 ± 7 %. The mean HMR values were 1.34 ± 0.15 and 1.45 ± 0.27 from A-SPECT and D-SPECT, respectively (p < 0.0001). After correction, Lin's concordance correlation showed an almost perfect concordance between corrected D-SPECT HMR and A-SPECT HMR, and Bland-Altman analysis demonstrated a high agreement between the two measurements.

conclusionThe ADRECARD study demonstrated that determination of late HMR during cardiac MIBG imaging using dual isotope ((123)I and (99m)Tc) acquisition on a CZT camera (D-SPECT) is feasible in patients with heart failure. A linear correction based on the phantom study yielded a high agreement between (123)I MIBG HMR obtained using a CZT camera and that from conventional planar imaging.

Indexed as

3-IodobenzylguanidineGamma CamerasOrganophosphorus CompoundsOrganotechnetium CompoundsAdultAgedFemaleHeartHeart FailureHumansMaleMediastinumMiddle AgedPhantoms, ImagingTomography, Emission-Computed, Single-Photon3-IodobenzylguanidineOrganophosphorus CompoundsOrganotechnetium Compoundstechnetium tc-99m tetrofosminCZTD-SPECTDual isotopeHeart failureHeart-to-mediastinum ratioMIBG

Identifiers

PMID26227533
OpenAlexW1104123386

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.