Evidence map›Paper›PMID 26223864›Full record

ArticleJournal of clinical monitoring and computing2016

Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.

Roland Tomasi, Stephan Prueckner, Stephan Czerner, Renè Schramm, Gerhard Preissler, Bernhard Zwißler, Vera von Dossow-Hanfstingl

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Journal of clinical monitoring and computing, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Roland TomasiDepartment of Anaesthesiology, University of Munich, Marchionistrasse 15, 81377, Munich, Germany.
Stephan PruecknerInstitute for Emergency Medicine and Management in Medicine, University of Munich, Schillerstrasse 53, 80336, Munich, Germany.
Stephan CzernerDepartment of Anaesthesiology, University of Munich, Marchionistrasse 15, 81377, Munich, Germany.
Renè SchrammClinic of Cardiac Surgery, University of Munich, Marchionistrasse 15, 81377, Munich, Germany.
Gerhard PreisslerDepartment of General Thoracic Surgery, University of Munich, Marchionistrasse 15, 81377, Munich, Germany.
Bernhard ZwißlerDepartment of Anaesthesiology, University of Munich, Marchionistrasse 15, 81377, Munich, Germany.
Vera von Dossow-HanfstinglDepartment of Anaesthesiology, University of Munich, Marchionistrasse 15, 81377, Munich, Germany. vera.dossow@med.uni-muenchen.de.
Institut für Urheber- und Medienrecht · DELudwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to compare a continuous non-calibrated left heart cardiac index (CI) measurement by arterial waveform analysis (FloTrac(®)/Vigileo(®)) with a continuous calibrated right heart CI measurement by pulmonary artery thermodilution (CCOmbo-PAC(®)/Vigilance II(®)) for hemodynamic monitoring during lung transplantation. CI was measured simultaneously by both techniques in 13 consecutive lung transplants (n = 4 single-lung transplants, n = 9 sequential double-lung transplants) at distinct time points perioperatively. Linear regression analysis and Bland-Altman analysis with percentage error calculation were used for statistical comparison of CI measurements by both techniques. In this study the FloTrac(®) system underestimated the CI in comparison with the continuous pulmonary arterial thermodilution (p < 0.000). For all measurement pairs we calculated a bias of -0.55 l/min/m(2) with limits of agreement between -2.31 and 1.21 l/min/m(2) and a percentage error of 55 %. The overall correlations before clamping a branch oft the pulmonary artery (percentage error 41 %) and during the clamping periods of a branch oft the pulmonary artery (percentage error 66 %) failed to reached the required percentage error of less than 30 %. We found good agreement of both CI measurements techniques only during the measurement point "15 min after starting the second one-lung ventilation period" (percentage error 30 %). No agreement was found during all other measurement points. This pilot study shows for the first time that the CI of the FloTrac(®) system is not comparable with the continuous pulmonary-artery thermodilution during lung transplantation including the time periods without clamping a branch of the pulmonary artery. Arterial waveform and continuous pulmonary artery thermodilution are, therefore, not interchangeable during these complex operations.

Indexed as

Cardiac OutputLung TransplantationAdultAgedFemaleHemodynamicsHumansLinear ModelsMaleMiddle AgedMonitoring, IntraoperativePilot ProjectsProspective StudiesPulmonary ArteryPulse Wave AnalysisThermodilutionArterial waveform analysisCardiac indexCardiac outputFloTrac® systemLung transplantationPulmonary artery catheter

Identifiers

PMID26223864
OpenAlexW996907314

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.