Evidence map›Paper›PMID 26216293›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2016

A priori model independent inverse potential mapping: the impact of electrode positioning.

A W Maurits van der Graaf, Pranav Bhagirath, Jacques de Hooge, Natasja M S de Groot, Marco J W Götte

Abstract read
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. [Study on precise localization of intraoperative matrix electrode].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2017
    Article
  5. Non-invasive focus localization, right ventricular epicardial potential mapping in patients with an MRI-conditional pacemaker system - a pilot study.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

A W Maurits van der GraafDepartment of Cardiology, Haga Teaching Hospital, Leyweg 275, 2545 CH, The Hague, The Netherlands. a.vandergraaf@hagaziekenhuis.nl.
Pranav BhagirathDepartment of Cardiology, Haga Teaching Hospital, Leyweg 275, 2545 CH, The Hague, The Netherlands.
Jacques de HoogeDepartment of Cardiology, Haga Teaching Hospital, Leyweg 275, 2545 CH, The Hague, The Netherlands.
Natasja M S de GrootDepartment of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands.
Marco J W GötteDepartment of Cardiology, Haga Teaching Hospital, Leyweg 275, 2545 CH, The Hague, The Netherlands. mjw.gotte@hagaziekenhuis.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn inverse potential mapping, local epicardial potentials are computed from recorded body surface potentials (BSP). When BSP are recorded with only a limited number of electrodes, in general biophysical a priori models are applied to facilitate the inverse computation. This study investigated the possibility of deriving epicardial potential information using only 62 torso electrodes in the absence of an a priori model.

methodsComputer simulations were used to determine the optimal in vivo positioning of 62 torso electrodes. Subsequently, three different electrode configurations, i.e., surrounding the thorax, concentrated precordial (30 mm inter-electrode distance) and super-concentrated precordial (20 mm inter-electrode distance) were used to record BSP from three healthy volunteers. Magnetic resonance imaging (MRI) was performed to register the electrode positions with respect to the anatomy of the patient. Epicardial potentials were inversely computed from the recorded BSP. In order to determine the reconstruction quality, the super-concentrated electrode configuration was applied in four patients with an implanted MRI-conditional pacemaker system. The distance between the position of the ventricular lead tip on MRI and the inversely reconstructed pacing site was determined.

resultsThe epicardial potential distribution reconstructed using the super-concentrated electrode configuration demonstrated the highest correlation (R = 0.98; p < 0.01) with the original epicardial source model. A mean localization error of 5.3 mm was found in the pacemaker patients.

conclusionThis study demonstrated the feasibility of deriving detailed anterior epicardial potential information using only 62 torso electrodes without the use of an a priori model.

Indexed as

Computer SimulationPacemaker, ArtificialAdultAgedBody Surface Potential MappingElectrodesFeasibility StudiesHumansMagnetic Resonance ImagingMaleMiddle AgedModels, AnatomicBody surface potential mappingComputational cardiac electrophysiologyInverse proceduresNon-invasive imaging

Identifiers

PMID26216293
PMCPMC4712232

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.