Evidence map›Paper›PMID 26209758›Full record

ArticleInternational journal of surgery case reports2015

A case of a colocutaneous fistula: A rare complication of mesh migration into the sigmoid colon after open tension-free hernia repair.

Saud Al-Subaie, Mohanned Al-Haddad, Wadha Al-Yaqout, Mufarrej Al-Hajeri, Christiano Claus

Open access · goldAbstract read
In one paragraph

Article in International journal of surgery case reports, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Mesh migration into an inguinal hernia sac following a laparoscopic umbilical hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2018
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Saud Al-SubaieClínica IJP - Instituto Jacques Perissat, Curitiba, Brazil.
Mohanned Al-HaddadClínica IJP - Instituto Jacques Perissat, Curitiba, Brazil. Electronic address: Dr.moq8@hotmail.co.uk.
Wadha Al-YaqoutClínica IJP - Instituto Jacques Perissat, Curitiba, Brazil.
Mufarrej Al-HajeriClínica IJP - Instituto Jacques Perissat, Curitiba, Brazil.
Christiano ClausClínica IJP - Instituto Jacques Perissat, Curitiba, Brazil.
IAC (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe Lichtenstein technique is commonly used in inguinal hernia repair and a polypropylene mesh is the most frequently used mesh. Mesh migration into the colon has been rarely reported in the literature. Here we report a case of a colocutaneous fistula that developed following delayed mesh migration into the sigmoid colon. PRESENTATION OF CASE: A 52-year-old man undergone Lichtenstein repair for left direct inguinal herniain 2008. Three years later, he presented complaining of rectal bleeding and concurrent bloody discharge from the hernia repair scar. Colonoscopy identified an internal fistulous orifice with intraluminal extrusion of the polypropylene mesh. Furthermore, abdominal ultrasound revealed a fistulous tract extending from the sigmoid colon to the anterior abdominal wall, and a fistulogram confirmed the findings. Open sigmoidectomy and resection of the abdominal wall with the fistula tract was performed, and BIO-A(®) tissue reinforcement meshwas placed. His postoperative course was unremarkable and was discharged on postoperative day 3. DISCUSSION: Mesh migration after mesh inguinal hernia repair is unpredictable. A previous report has presented complications related to prosthetics in hernia repair, such as infection, contraction, rejection, and, rarely, mesh migration.Mesh migration may occur as an early or late complication after hernioplasty.

conclusionDuring hernia repair, the surgeon should carefully check for a sliding hernia, which may contain the sigmoid colon within the sac, because failure to identify this hernia may lead to direct contact between the mesh and the colon, which may cause pressure necrosis and fistula formation followed by mesh migration.

Indexed as

ComplicationsFistulaHerniaMesh migrationRare

Identifiers

PMID26209758
PMCPMC4573409
OpenAlexW1792925119

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.