Evidence map›Paper›PMID 26207142›Full record

ArticleJournal of foot and ankle research2015

The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion.

Simon J Otter, Brunilda Agalliu, Nicola Baer, Georgie Hales, Katrina Harvey, Keeley James, Richard Keating, Warren McConnell, Rachel Nelson, Saddaf Qureshi and 5 more

Open access · goldAbstract read
In one paragraph

Article in Journal of foot and ankle research, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
7.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 71 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Validity and Reliability of the WIMUInternational journal of environmental research and public health · 2019
    Article
  15. Article
  16. Observational
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 1 institution in 1 country.

Simon J OtterSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Brunilda AgalliuSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Nicola BaerSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Georgie HalesSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Katrina HarveySchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Keeley JamesSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Richard KeatingSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Warren McConnellSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Rachel NelsonSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Saddaf QureshiSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Steven RyanSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Abigail St JohnSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Heather WaddingtonSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Katie WarrenSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Duane WongSchool of Health Science, 49 Darley Rd, Eastbourne, BN20 7UR UK.
Eastbourne District General Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdequate sagittal plane motion of the first metatarsalphalangeal joint (1st MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool. We aimed to determine the intra and inter-rater reliability together with the concurrent validity of a universal plastic goniometer (UG) and a smartphone applicationlication (Dr G) for the measurement of dorsiflexion at the 1st MTPJ.

methodsMeasurement of joint position and passive range of motion of the 1st MTPJ dorsiflexion was compared using a UG and DrG goniometer. A double-blind repeated measures design was utilized, with intraclass correlation coefficient (ICC) used to determine levels of reliability.

resultsFor joint position good intra-rater reliability (ICC >0.861) and good inter-rater reliability (ICC >0.823) was noted. However, the Dr G application consistently measured lower angles (mean 27.8° (SD 8.37)) than the UG (mean 32° (SD 11.7)) and these associations were significant (r = 0.399, p < 0.001). For passive range of motion, the mean total range of dorsiflexion motion (from maximum plantarflexed position to maximum dorsiflexed position) was 82.8° (SD 12.2) for the UG and 82.9° (SD 11.3) for the Dr G application. Both instruments demonstrated high levels of intra-rater reliability (ICC >0.809). Inter-rater reliability was moderate to good for the UG (ICC 0.693 (95 % CI 0.580 to 0.788)) and good for the Dr G application (ICC 0.708 (95 % CI 0.597 to 0.799)).

conclusionsModerate to high intra and inter-rater reliability of joint position and passive 1st MTPJ motion can be achieved with traditional and smartphone-based goniometric measurement. The Dr G application may provide a slightly higher reliability, but devices should not be used inter-changeably as significant variation in measurement between devices may occur.

Indexed as

Biomechanics Cell phoneFirst metatarsophalangeal jointReproducibility of results

Identifiers

PMID26207142
PMCPMC4512018
OpenAlexW2168113222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.