Evidence map›Paper›PMID 26206689›Full record

ArticleAnnals of laboratory medicine2015

Development and validation of liquid chromatography-tandem mass spectrometry method for quantification of plasma metanephrines for differential diagnosis of adrenal incidentaloma.

Sae Mi Lee, Mi Na Lee, Hyeon Ju Oh, Yoon Young Cho, Jae Hyeon Kim, Hye In Woo, Hyung Doo Park, Soo Youn Lee

Open access · diamondAbstract readEvaluation Study
In one paragraph

Article in Annals of laboratory medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Sae Mi LeeDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Mi Na LeeDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Hyeon Ju OhDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Yoon Young ChoDepartment of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Jae Hyeon KimDepartment of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Hye In WooDepartment of Laboratory Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Korea.
Hyung Doo ParkDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Soo Youn LeeDepartment of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. suddenbz@skku.edu.
Samsung Medical Center · KRSamsung (South Korea) · KRSungkyunkwan University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clinical efficacy in differential diagnosis of adrenal incidentaloma. After solid-phase extraction, chromatographic isolation of the analytes and internal standard was achieved by column elution in the LC-MS/MS system. The analytes were detected in multiple-reaction monitoring mode by using positive electrospray ionization: MN, transition m/z 180.1-->165.1; NMN, m/z 166.1-->134.1. This method was validated for linearity, precision, accuracy, lower limits of quantification and detection, extraction recovery, and the matrix effect. Plasma concentrations of MN and NMN of 14 patients with pheochromocytoma were compared with those of 17 healthy volunteers, 10 patients with essential hypertension, and 60 patients with adrenal adenoma. The assay's linear range was 0.04-50.0 and 0.08-100.0 nmol/L for MN and NMN, respectively. Assay imprecision was 1.86-7.50%. The accuracy ranged from -7.50% to 2.00%, and the mean recovery of MN and NMN was within the range 71.5-95.2%. Our LC-MS/MS method is rapid, accurate, and reliable and useful for differential diagnosis of adrenal incidentaloma.

Indexed as

Chromatography, High Pressure LiquidTandem Mass SpectrometryAdrenal Gland NeoplasmsCase-Control StudiesDiagnosis, DifferentialHumansMetanephrineNormetanephrinePheochromocytomaSolid Phase ExtractionMetanephrineNormetanephrineMass spectrometryMetanephrinesPheochromocytomaPlasmaValidation

Identifiers

PMID26206689
PMCPMC4510505
OpenAlexW1752652047

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.