Evidence map›Paper›PMID 26206260›Full record

ArticleInternational orthopaedics2016

Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

José Figueroa, Juan Pablo Guarachi, José Matas, Magnus Arnander, Mario Orrego

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
5.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 31 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2023
    Article
  5. Article
  6. Failure modes in malrotated total knee replacement.Archives of orthopaedic and trauma surgery · 2023
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 3 countries.

José FigueroaKnee Surgery Unit, Hospital Militar de Santiago, Av. Alcalde Fernando Castillo Velasco 9100, Santiago, Chile.
Juan Pablo GuarachiDepartment of Orthopedics, School of Medicine, Universidad de los Andes, Mons. Álvaro del Portillo, 12.455, Santiago, Chile. jpguarachi@gmail.com.
José MatasDepartment of Orthopedics, School of Medicine, Universidad de los Andes, Mons. Álvaro del Portillo, 12.455, Santiago, Chile.
Magnus ArnanderDepartment of Orthopaedic Surgery St George's Hospital, Blackshaw Road, Tooting, London, SW17 0QT, UK.
Mario OrregoKnee Surgery Unit, Hospital Militar de Santiago, Av. Alcalde Fernando Castillo Velasco 9100, Santiago, Chile.
Universidad de Los Andes, Chile · CLClínica Dávila · CLSt George's Hospital · GBUniversidad de Los Andes · CO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeComputed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation.

methodsTKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability.

resultsFemoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively.

conclusionsCT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.

Indexed as

AgedArthroplasty, Replacement, KneeFemaleHumansKnee JointMaleMiddle AgedReproducibility of ResultsRotationTomography, X-Ray ComputedAccuracyComputed tomographyMalrotationReliabilityRotationTotal knee arthroplasty

Identifiers

PMID26206260
OpenAlexW1474414666

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.