Evidence map›Paper›PMID 26200860›Full record

ArticleBiophysical journal2015

Evaluating the performance of time-gated live-cell microscopy with lanthanide probes.

Megha Rajendran, Lawrence W Miller

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Biophysical journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 40 citations in OpenAlex.

  1. Development of Time-Resolved Luminescence Measurement Instruments for Biosensing and Bioimaging - An Overview.Measurement : journal of the International Measurement Confederation · 2025
    Article
  2. Article
  3. Review
  4. Article
  5. Long-lived lanthanide emissionChemical science · 2021
    Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Megha RajendranDepartment of Chemistry, University of Illinois at Chicago, Chicago, Illinois.
Lawrence W MillerDepartment of Chemistry, University of Illinois at Chicago, Chicago, Illinois. Electronic address: lwm2006@uic.edu.
University of Illinois Chicago · US

Funding

Targeted lanthanide contrast agents for in cellulo single molecule imagingR01GM081030 · NIGMS · UNIVERSITY OF ILLINOIS AT CHICAGO · PI MILLER, LAWRENCE · 2008 to 2018
$2.5M
NIGMS NIH HHS R01 GM081030NIGMS NIH HHS R01GM081030
6 · The paper itself

Abstract

Probes and biosensors that incorporate luminescent Tb(III) or Eu(III) complexes are promising for cellular imaging because time-gated microscopes can detect their long-lifetime (approximately milliseconds) emission without interference from short-lifetime (approximately nanoseconds) fluorescence background. Moreover, the discrete, narrow emission bands of Tb(III) complexes make them uniquely suited for multiplexed imaging applications because they can serve as Förster resonance energy transfer (FRET) donors to two or more differently colored acceptors. However, lanthanide complexes have low photon emission rates that can limit the image signal/noise ratio, which has a square-root dependence on photon counts. This work describes the performance of a wide-field, time-gated microscope with respect to its ability to image Tb(III) luminescence and Tb(III)-mediated FRET in cultured mammalian cells. The system employed a UV-emitting LED for low-power, pulsed excitation and an intensified CCD camera for gated detection. Exposure times of ∼1 s were needed to collect 5-25 photons per pixel from cells that contained micromolar concentrations of a Tb(III) complex. The observed photon counts matched those predicted by a theoretical model that incorporated the photophysical properties of the Tb(III) probe and the instrument's light-collection characteristics. Despite low photon counts, images of Tb(III)/green fluorescent protein FRET with a signal/noise ratio ≥ 7 were acquired, and a 90% change in the ratiometric FRET signal was measured. This study shows that the sensitivity and precision of lanthanide-based cellular microscopy can approach that of conventional FRET microscopy with fluorescent proteins. The results should encourage further development of lanthanide biosensors that can measure analyte concentration, enzyme activation, and protein-protein interactions in live cells.

Indexed as

TerbiumAnimalsCalibrationDogsFluorescence Resonance Energy TransferGreen Fluorescent ProteinsLuminescenceMadin Darby Canine Kidney CellsMicroscopyPhotonsGreen Fluorescent ProteinsTerbium

Identifiers

PMID26200860
PMCPMC4621812
OpenAlexW1904034813

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.