ArticleBiophysical journal2015
Evaluating the performance of time-gated live-cell microscopy with lanthanide probes.
Article in Biophysical journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 40 citations in OpenAlex.
- Development of Time-Resolved Luminescence Measurement Instruments for Biosensing and Bioimaging - An Overview.Measurement : journal of the International Measurement Confederation · 2025Article
- Binuclear Lanthanide Complexes as Magnetic Resonance and Optical Imaging Probes for Redox Sensing.Chemistry (Weinheim an der Bergstrasse, Germany) · 2025Article
- Luminescent Lanthanides in Biorelated Applications: From Molecules to Nanoparticles and Diagnostic Probes to Therapeutics.Chemical reviews · 2025Review
- Low-rate smartphone videoscopy for microsecond luminescence lifetime imaging with machine learning.PNAS nexus · 2023Article
- Long-lived lanthanide emissionChemical science · 2021Article
- Applying TADF Emitters in Bioimaging and Sensing-A Novel Approach Using Liposomes for Encapsulation and Cellular Uptake.Frontiers in chemistry · 2021Article
- Lanthanide-Based Optical Probes of Biological Systems.Cell chemical biology · 2020Review
- Ultrasensitive optical imaging with lanthanide lumiphores.Nature chemical biology · 2018Article
- Time Gated Luminescence Imaging of Immunolabeled Human Tissues.Analytical chemistry · 2017Article
- Brightly Luminescent and Kinetically Inert Lanthanide Bioprobes Based on Linear and Preorganized Chelators.Bioconjugate chemistry · 2016Article
- Time-gated FRET nanoassemblies for rapid and sensitive intra- and extracellular fluorescence imaging.Science advances · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
Probes and biosensors that incorporate luminescent Tb(III) or Eu(III) complexes are promising for cellular imaging because time-gated microscopes can detect their long-lifetime (approximately milliseconds) emission without interference from short-lifetime (approximately nanoseconds) fluorescence background. Moreover, the discrete, narrow emission bands of Tb(III) complexes make them uniquely suited for multiplexed imaging applications because they can serve as Förster resonance energy transfer (FRET) donors to two or more differently colored acceptors. However, lanthanide complexes have low photon emission rates that can limit the image signal/noise ratio, which has a square-root dependence on photon counts. This work describes the performance of a wide-field, time-gated microscope with respect to its ability to image Tb(III) luminescence and Tb(III)-mediated FRET in cultured mammalian cells. The system employed a UV-emitting LED for low-power, pulsed excitation and an intensified CCD camera for gated detection. Exposure times of ∼1 s were needed to collect 5-25 photons per pixel from cells that contained micromolar concentrations of a Tb(III) complex. The observed photon counts matched those predicted by a theoretical model that incorporated the photophysical properties of the Tb(III) probe and the instrument's light-collection characteristics. Despite low photon counts, images of Tb(III)/green fluorescent protein FRET with a signal/noise ratio ≥ 7 were acquired, and a 90% change in the ratiometric FRET signal was measured. This study shows that the sensitivity and precision of lanthanide-based cellular microscopy can approach that of conventional FRET microscopy with fluorescent proteins. The results should encourage further development of lanthanide biosensors that can measure analyte concentration, enzyme activation, and protein-protein interactions in live cells.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.