ArticleMagnetic resonance in medicine2016
Improvement of temporal signal-to-noise ratio of GRAPPA accelerated echo planar imaging using a FLASH based calibration scan.
Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed.
- Magnetization transfer weighted EPI facilitates cortical depth determination in native fMRI space.NeuroImage · 2021Trial
- 7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane BMagnetic resonance in medicine · 2026Article
- Assessing cerebral microvascular volumetric with high-resolution 4D cerebral blood volume MRI at 7 T.Nature cardiovascular research · 2025Article
- Exploiting four-way phase-encoding benefits for robust detection and correction of EPI artifacts: Application to residual ghosts in diffusion MRI.Magnetic resonance imaging · 2025Article
- 3D MERMAID: 3D Multi-shot enhanced recovery motion artifact insensitive diffusion for submillimeter, multi-shell, and SNR-efficient diffusion imaging.Magnetic resonance in medicine · 2025Article
- Assessing Cerebral Microvascular Volumetric Pulsatility with High-Resolution 4D CBV MRI at 7T.medRxiv : the preprint server for health sciences · 2024Article
- Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography.Radiological physics and technology · 2024Article
- Thermal stimulus task fMRI in the cervical spinal cord at 7 Tesla.Human brain mapping · 2024Article
- Characterisation of laminar and vascular spatiotemporal dynamics of CBV and BOLD signals using VASO and ME-GRE at 7T in humans.bioRxiv : the preprint server for biology · 2024Article
- Customization of neonatal functional magnetic resonance imaging: A preclinical phantom-based study.PloS one · 2024Article
- Characterisation of laminar and vascular spatiotemporal dynamics of CBV and BOLD signals using VASO and ME-GRE at 7T in humans.Imaging neuroscience (Cambridge, Mass.) · 2024Article
- Imaging the columnar functional organization of human area MT+ to axis-of-motion stimuli using VASO at 7 Tesla.Cerebral cortex (New York, N.Y. : 1991) · 2023Article
- Impact of autocalibration method on accelerated EPI of the cervical spinal cord at 7 T.Magnetic resonance in medicine · 2022Article
- Layer-dependent functional connectivity methods.Progress in neurobiology · 2021Review
- Rapid head-pose detection for automated slice prescription of fetal-brain MRI.International journal of imaging systems and technology · 2021Article
- High-resolution fMRI at 7 Tesla: challenges, promises and recent developments for individual-focused fMRI studies.Current opinion in behavioral sciences · 2021Article
- Robust autocalibrated structured low-rank EPI ghost correction.Magnetic resonance in medicine · 2021Article
- Noise power spectrum in compressed sensing magnetic resonance imaging.Radiological physics and technology · 2021Article
- Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7 T.PloS one · 2021Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeTo demonstrate that the temporal signal-to-noise ratio (SNR) of generalized autocalibrating partially parallel acquisitions (GRAPPA) accelerated echo planar imaging (EPI) can be enhanced and made more spatially uniform by using a fast low angle shot (FLASH) based calibration scan.
methodsEPI of a phantom and human brains were acquired at 3 Tesla without and with GRAPPA acceleration factor of 2. The GRAPPA accelerated data were reconstructed using calibration scans acquired with EPI and FLASH acquisition schemes. The increase in temporal signal fluctuation due to GRAPPA reconstruction was quantified and compared. Simulated g-factor maps were also created for different calibration scans.
resultsGRAPPA accelerated phantom data exhibited areas with high g values when using the EPI based calibration for reconstruction. The g-factor maps were uniform when using the FLASH calibration scan. g was greater than 1.1 in 74% of pixels in 64 × 64 data reconstructed with the EPI calibration compared with only 15% when using the FLASH calibration scan. Human data also showed abnormally high g regions when using the EPI calibration but not when using the FLASH calibration scan. Use of the FLASH calibration scan increased the whole brain temporal SNR by ∼12% without affecting the image quality. Experimental observations were confirmed by simulations.
conclusionA calibration scan based on a FLASH acquisition scheme can be used to improve the temporal SNR of GRAPPA accelerated EPI time series. Magn Reson Med 75:2362-2371, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials