Observational studyBMC surgery2015
The TICAP-Study (titanium clips for appendicular stump closure): A prospective multicentre observational study on appendicular stump closure with an innovative titanium clip.
Observational study in BMC surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01734837 (Prospective Multicenter Observational Study), which is not on this map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prospective Multicenter Observational Study (Registry) on the Aesculap DS Titanium Ligation Clips for Appendiceal Stump Closure.
Who cites it
10 citing papers in PubMed.
- A randomized clinical trial of technical modifications of appendix stump closure during laparoscopic appendectomy for uncomplicated acute appendicitis.BMC surgery · 2021Trial
- The influence of the different forms of appendix base closure on patient outcome in laparoscopic appendectomy: a randomized trial.Surgical endoscopy · 2018Trial
- Absorbable polymeric surgical clips for appendicular stump closure: A randomized control trial of laparoscopic appendectomy with lapro-clips.Oncotarget · 2016Trial
- Appendiceal stump closure in laparoscopic appendectomy: one endoloop vs. two endoloops vs. two endoclips-does it matter?Langenbeck's archives of surgery · 2023Article
- Closure of the appendiceal stump in laparoscopic appendectomy: A systematic review of the literature.Annals of medicine and surgery (2012) · 2020Review
- The Influence of the Appendiceal Base Diameter on Appendix Stump Closure in Laparoscopic Appendectomy.World journal of surgery · 2016Article
- Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study.Innovative surgical sciences · 2016Article
- Tissue Reaction and the Formation of Adhesion after the Use of DS Clip in Laparoscopic Appendectomy.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
- Comparison of Stump Closure Methods in Laparoscopic Appendectomy: Hem-o-Lok Clip and Laparoscopic Titanium Clip.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
- Laparoscopic Appendectomy versus Open Surgery.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo evaluate the effectiveness and safety of the DS Titanium Ligation Clip for appendicular stump closure in laparoscopic appendectomy.
methodsOverall, 502 patients undergoing laparoscopic appendectomy were recruited for this observational multicentre study in nine study centres between October 2011 and July 2013. The clip was finally applied in 390 patients. Primary outcome variables were feasibility of the clip, intra-abdominal surgical site (abscesses, stump leakages) and superficial wound infections. Patients were followed 30 days after surgery.
resultsThe clip was applicable in nearly 80 % of patients. Reasons for not applying the clip were mainly an inflamed caecum or a too large diameter of the appendix base. Superficial wound infections were found in nine (2.31 %), intra-abdominal abscesses in five (1.28 %), appendicular stump leak in one (0.26 %), and other adverse events in 22 (5.64 %) patients. In total, 12 (3.08 %) patients were re-admitted to hospital for treatment. Seven re-admissions were surgery-related; ten (2.56 %) patients had to be re-operated. One patient died during the course of the study due to persisting peritonitis (mortality 0.26 %).
conclusionsThe results suggest that the DS Titanium Ligation Clip is a safe and effective option in securing the appendicular stump in laparoscopic appendectomy. The complication rates found with the use of the DS-Clip are comparable to the rates in the literature when other methods are used.
trial registrationNCT01734837 .
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.