Evidence map›Paper›PMID 26180723›Full record

ArticlePlastic and reconstructive surgery. Global open2015

The "Inside-out" Technique for Hernia Repair with Mesh Underlay.

Aaron E Berhanu, Simon G Talbot

Open access · goldAbstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Aaron E BerhanuDivision of Plastic Surgery, Department of Surgery, Brigham and Women's Hospital, Boston, Mass.
Simon G TalbotDivision of Plastic Surgery, Department of Surgery, Brigham and Women's Hospital, Boston, Mass.
Brigham and Women's Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn improved method for mesh repair of ventral/incisional hernias after component separation is presented. The use of a Carter-Thomason suture passer (Cooper Surgical, http://www.coopersurgical.com) allows for safe passage of preplaced sutures on the mesh from within the abdominal cavity through the anterior rectus sheath. This "inside-out" method makes the underlay of mesh fast and easy by improving visualization and control of sharp instruments as they are passed through the abdominal cavity. Preplacement of sutures circumferentially on the mesh also improves the distribution of tension around the repair, which may ultimately reduce the risk of hernia recurrence.

methodsThe "inside-out" technique was performed on 23 patients at a single tertiary academic medical center from November 2011 to February 2014. We have followed these patients for a median of 24.5 months to assess for postoperative complications and hernia recurrence.

resultsWe report an acceptable hernia recurrence rate (2 of 23 = 8.7%). One recurrence was observed in a patient who underwent repair of a recurrent ventral hernia and the other had significant loss of domain requiring an inlay mesh.

conclusionsThe "inside-out" technique for ventral hernia repair with a mesh underlay after component separation using a Carter-Thomason suture passer is easy, safe, and reliable. We have observed no hernia recurrence in patients who underwent repair for a primary ventral hernia with an underlay technique.

Identifiers

PMID26180723
PMCPMC4494492
OpenAlexW1199027194

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.