Evidence map›Paper›PMID 26180704›Full record

ReviewCureus2015

Ultrasound Imaging in Radiation Therapy: From Interfractional to Intrafractional Guidance.

Craig Western, Dimitre Hristov, Jeffrey Schlosser

Open access · diamondAbstract readReview
In one paragraph

Review in Cureus, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
5.4field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2021
    Article
  6. Article
  7. 3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2021
    Article
  8. Article
  9. Article
  10. Review
  11. Development of a robot-assisted ultrasound-guided radiation therapy (USgRT).International journal of computer assisted radiology and surgery · 2020
    Article
  12. Analysis and optimization of the robot setup for robotic-ultrasound-guided radiation therapy.International journal of computer assisted radiology and surgery · 2019
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Craig WesternDepartment of Mechanical Engineering, Stanford University.
Dimitre HristovDepartment of Radiation Oncology, Stanford University.
Jeffrey SchlosserFounder, SoniTrack Systems.
Stanford University · US

Funding

Robotic Ultrasound Image Guidance System for Radiation TherapyR41CA174089 · NCI · SONITRACK SYSTEMS, INC. · PI HRISTOV, DIMITRE HRISTOV, SCHLOSSER, JEFFREY STEVEN · 2012 to 2013
$379k
NCI NIH HHS R41 CA174089
6 · The paper itself

Abstract

External beam radiation therapy (EBRT) is included in the treatment regimen of the majority of cancer patients. With the proliferation of hypofractionated radiotherapy treatment regimens, such as stereotactic body radiation therapy (SBRT), interfractional and intrafractional imaging technologies are becoming increasingly critical to ensure safe and effective treatment delivery. Ultrasound (US)-based image guidance systems offer real-time, markerless, volumetric imaging with excellent soft tissue contrast, overcoming the limitations of traditional X-ray or computed tomography (CT)-based guidance for abdominal and pelvic cancer sites, such as the liver and prostate. Interfractional US guidance systems have been commercially adopted for patient positioning but suffer from systematic positioning errors induced by probe pressure. More recently, several research groups have introduced concepts for intrafractional US guidance systems leveraging robotic probe placement technology and real-time soft tissue tracking software. This paper reviews various commercial and research-level US guidance systems used in radiation therapy, with an emphasis on hardware and software technologies that enable the deployment of US imaging within the radiotherapy environment and workflow. Previously unpublished material on tissue tracking systems and robotic probe manipulators under development by our group is also included.

Indexed as

image guidanceimage-guided radiation therapyimage-guided therapyliver cancerprostate cancerreal-time systemroboticstreatment planningultrasound

Identifiers

PMID26180704
PMCPMC4494460
OpenAlexW1584909366

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.