Evidence map›Paper›PMID 26179576›Full record

ArticleJournal of feline medicine and surgery2016

Simultaneous visual inspection for barometric whole-body plethysmography waveforms during pulmonary function testing in client-owned cats.

Chung-Hui Lin, Huey-Dong Wu, Pei-Ying Lo, Jih-Jong Lee, Chen-Hsuan Liu

Abstract readEvaluation Study
In one paragraph

Article in Journal of feline medicine and surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chung-Hui LinGraduate Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan Section of Small Animal Internal Medicine, National Taiwan University Veterinary Hospital, Taipei, Taiwan.
Huey-Dong WuSection of Respiratory Therapy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan.
Pei-Ying LoSection of Small Animal Internal Medicine, National Taiwan University Veterinary Hospital, Taipei, Taiwan.
Jih-Jong LeeGraduate Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan Section of Small Animal Internal Medicine, National Taiwan University Veterinary Hospital, Taipei, Taiwan Graduate Institute of Veterinary Clinical Sciences, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan.
Chen-Hsuan LiuGraduate Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan Graduate Institute of Molecular and Comparative Pathobiology, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan Section of Diagnostic Pathology, National Taiwan University Veterinary Hospital, Taipei, Taiwan chhsuliu@ntu.edu.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFor the purpose of applying a barometric whole-body plethysmography (BWBP) device as a routine clinical tool in client-owned cats, the objective of this study was to evaluate the methodological importance of simultaneous visual inspection (SVI) of graphic tracing.

methodsTo investigate the effect of SVI on the results obtained, 50 client-owned cats were included. Breath-by-breath analysis was conducted with BWBP software, and a commonly used rejection setting was chosen for automatic elimination (AE) of non-breath artefactual waveforms, according to tidal volume (TV), inspiratory and expiratory time, and the difference between inspiratory and expiratory volumes. During 10 mins of data recording, SVI for BWBP waveforms was performed to record manually time periods that were free of any artefacts. The two datasets derived from AE alone (AEA method) and AE plus SVI (SVI-AE method) were compared. The inter-observer effect on the process of SVI was evaluated on six cats.

resultsThere were statistically significant differences (P <0.001) between the AEA and SVI-AE datasets for most BWBP parameters. Bland-Altman analysis of the parameter-enhanced pause (Penh) showed heterogeneous variances, indicating less agreement when the Penh values were large. Intra-individual coefficients of variation of Penh were significantly higher with the AEA method than with the SVI-AE method (61.1% vs 34.7%, respectively; P <0.001). Inter-observer agreement on the SVI process was excellent, and no statistically significant differences between the two observers were found for any BWBP parameters obtained by the SVI-AE method (P >0.05). CONCLUSIONS AND RELEVANCE: Visual inspection for BWBP waveforms in real time can reliably identify stable breathing signals in client-owned cats. The obtained results were significantly different when the SVI method was used in addition to AE. In the interpretation of BWBP parameters or comparison of measurements among studies, whether an SVI methodology was applied should be considered.

Indexed as

AnimalsCase-Control StudiesCat DiseasesCatsFemaleLung Diseases, ObstructiveMaleObserver VariationPlethysmography, Whole BodyReproducibility of ResultsRespiratory Function TestsSensitivity and SpecificityTidal Volume

Identifiers

PMID26179576
PMCPMC11112210

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.