ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2015
Intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complex intracranial aneurysms.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- The "pipe-anchor" technique: A method for intra-aneurysmal loop reduction using a partially unsheathed pipeline stent.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Distal anchoring techniques for reducing intra-aneurysmal (around-the-world) microcatheter loop prior to stent deployment across large wide-necked aneurysms- an educational review.Neuroradiology · 2025Review
- Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.Journal of neurosurgery. Case lessons · 2024Article
- Steerable microcatheter for distal access of a giant cavernous carotid artery aneurysm during treatment with Pipeline Embolization Device: A case report and review of the literature.Surgical neurology international · 2024Article
- Horizontal stenting via retrograde route for recurrent ruptured posterior communicating artery aneurysm after clipping: A case report and literature review.Clinical case reports · 2022Article
- Endovascular repair of a complex renal artery aneurysm using PipelineJournal of radiology case reports · 2021Article
- Retrograde T-Stent Technique for Large, Wide-Necked Internal Carotid-Posterior Communicating Artery Aneurysm.Journal of neuroendovascular therapy · 2021Article
- Residual Flow Inside the Woven EndoBridge Device at Follow-Up: Potential Predictors of the Bicêtre Occlusion Scale Score 1 Phenomenon.AJNR. American journal of neuroradiology · 2020Article
- The bumper technique for advancing a large profile microcatheter.BMJ case reports · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The endovascular treatment of wide-necked, large and giant aneurysms remains challenging. This retrospective study investigated the feasibility and safety of an intra-aneurysmal microcatheter looping technique for stent-assisted embolization of complicated intracranial aneurysms.This technique was used for 31 patients with complicated cerebral aneurysms from January 2007 to November 2013. The clinical and angiographic results were retrospectively evaluated.The target aneurysms were successfully treated in all cases (100%). A flow diverter was used in seven procedures. There were no aneurysmal perforations or ischemic complications, except for a microguidewire perforation of the distal vessel in one case. Among the 24 cases with conventional stent-assisted embolization, complete embolization or neck residual was obtained in 21 cases. Partial occlusion occurred in three cases.In conclusion, the intra-aneurysmal microcatheter looping technique is a safe and feasible alternative treatment of complicated intracranial aneurysms. This approach is a reasonable choice for patients and leads to successful outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.