Evidence map›Paper›PMID 26178873›Full record

ArticleAnnals of biomedical engineering2016

In vivo Evaluation of Cenderitide-Eluting Stent (CES) II.

Yingying Huang, Xu Wen Ng, Soon Ghim Lim, Horng Haur Chen, John C Burnett, Yin Chiang Freddy Boey, Subbu S Venkatraman

Abstract readEvaluation Study
In one paragraph

Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Yingying HuangSchool of Materials Science & Engineering, Nanyang Technological University, Block N4.1-02-06 Nanyang Avenue, Singapore, 639798, Singapore. yingyinghuang@ntu.edu.sg.
Xu Wen NgSchool of Materials Science & Engineering, Nanyang Technological University, Block N4.1-02-06 Nanyang Avenue, Singapore, 639798, Singapore.
Soon Ghim LimSchool of Materials Science & Engineering, Nanyang Technological University, Block N4.1-02-06 Nanyang Avenue, Singapore, 639798, Singapore.
Horng Haur ChenDivision of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
John C BurnettDivision of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Yin Chiang Freddy BoeySchool of Materials Science & Engineering, Nanyang Technological University, Block N4.1-02-06 Nanyang Avenue, Singapore, 639798, Singapore.
Subbu S VenkatramanSchool of Materials Science & Engineering, Nanyang Technological University, Block N4.1-02-06 Nanyang Avenue, Singapore, 639798, Singapore. assubbu@ntu.edu.sg.
Nanyang Technological University · SGMayo Clinic · US

Funding

Cardiovascular Peptides and Myocardial InfarctionR01HL083231 · NHLBI · MAYO CLINIC ROCHESTER · PI BURNETT, JOHN C, CHEN, HORNG H · 2006 to 2016
$4.6M
NHLBI NIH HHS R01 HL083231
6 · The paper itself

Abstract

The use of drug-eluting coronary stents has led to significant reduction in in-stent restenosis (ISR), but led to delayed endothelialization, necessitating the prolonged use of expensive anti-thrombotic drugs with their side-effects. Cenderitide (CD-NP) is a novel anti-proliferative chimeric peptide of semi-endothelial origin. Our previous work in vitro has demonstrated; that the smooth muscle cells were inhibited significantly more than endothelial cells which is the desirable feature of an anti-restenosis drug. This work reports the effects of implantation of a centeritide-eluting stent (CES) on ISR and endothelialization in an in vivo model. CESs were produced by coating bare metallic stents with CD-NP entrapped in biodegradable poly(ε-caprolactone) using an ultrasonic spray coater. A total of 32 stents were successfully implanted into 16 pigs, and all animal survived for 28 days. The plasma levels of CD-NP were significantly higher in the CES group than in the control group (bare metal stents and polymer-coated stent) at post-stenting, indicating the successful release of CD-NP from the stent in vivo. Furthermore, SEM analysis results showed the greater endothelial coverage of the stent struts, as well as between the struts in CES group. Moreover, histological results showed mild inflammation, and low fibrin score at 28 days. However, plasma cGMP (second messenger, cyclic 3',5' guanosine monophosphate) does not show a significant difference, and the CES is also unable to show significant difference in terms on neointimal area and stenosis, in comparison to BMS at 28 days.

Indexed as

Absorbable ImplantsCoated Materials, BiocompatibleDrug-Eluting StentsMaterials TestingNatriuretic PeptidesSnake VenomsAnimalsEndothelial CellsFemalePolyestersSwinecenderitideCoated Materials, BiocompatibleNatriuretic PeptidespolycaprolactonePolyestersSnake VenomsCenderitide (CD-NP)In vivoNatriuretic peptideStent

Identifiers

PMID26178873
PMCPMC4715776
OpenAlexW898682486

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.