Evidence map›Paper›PMID 26170730›Full record

ArticleJournal of blood medicine2015

Predictors of atrial fibrillation recurrence after cryoballoon ablation.

Tolga Aksu, Erkan Baysal, Tümer Erdem Guler, Sukriye Ebru Golcuk, İsmail Erden, Kazim Serhan Ozcan

Open access · goldAbstract read
In one paragraph

Article in Journal of blood medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 2 pooled it
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 2 syntheses or guidelines pooled it, 23 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Decreasing time between first diagnosis of paroxysmal atrial fibrillation and cryoballoon ablation positively affects long-term consequences.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Tolga AksuDepartment of Cardiology, Derince Education and Research Hospital, Kocaeli, Turkey.
Erkan BaysalDepartment of Cardiology, Diyarbakir Education and Research Hospital, Diyarbakir, Turkey.
Tümer Erdem GulerDepartment of Cardiology, Derince Education and Research Hospital, Kocaeli, Turkey.
Sukriye Ebru GolcukDepartment of Cardiology, Faculty of Medicine, Koc University, Istanbul, Turkey.
İsmail ErdenDepartment of Cardiology, Derince Education and Research Hospital, Kocaeli, Turkey.
Kazim Serhan OzcanDepartment of Cardiology, Derince Education and Research Hospital, Kocaeli, Turkey.
Diyarbakır Askeri Hastanesi · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveCryoballoon ablation (CA) is a safe and efficient method for pulmonary vein isolation in the treatment of paroxysmal atrial fibrillation (AF). There are conflicting results about the predictors of AF recurrence. The aim of this study is to evaluate the role of hematological indices to predict AF recurrence after CA.

methodsA total of 49 patients (mean age 58.3±12.2 years, 51.02% female) with symptomatic paroxysmal AF underwent CA procedure. One hundred and sixty-eight pulmonary veins were used for pulmonary vein isolation with the second-generation cryoballoon. The hematological samples were obtained before and 24 hours after ablation.

resultsAt a mean follow-up of 10.2±2.4 months, the probability of being arrhythmia-free after a single procedure was 86%. Patients with AF recurrence had higher red cell distribution width levels (16.10%±1.44% vs 14.87%±0.48%, P=0.035). The neutrophil/lymphocyte ratio, erythrocyte sedimentation rate, and C-reactive protein levels were detected in the patients with or without recurrence. Left atrial diameter (46.28±4.30 mm vs 41.02±4.10 mm, P=0.002), duration of AF (6.71±4.57 years vs 3.59±1.72 years, P=0.003), and age (65.01±15.39 years vs 54.29±11.32 years, P=0.033) were the other independent predictors of clinical recurrence after CA. Multiple regression analysis revealed that left atrial diameter was the only independent predictor for AF recurrence (P=0.012).

conclusionIn this study of patients with paroxysmal AF undergoing cryoablation, increased preablation red cell distribution width levels, and not C-reactive protein or erythrocyte sedimentation rate, was associated with a higher rate of AF recurrence. Our results support the role of a preablation, proinflammatory, and pro-oxidant environment in the development of AF recurrence after ablation therapy but suggest that other factors are also important.

Indexed as

ablationatrial fibrillationCRPcryoballoonneutrophiloxidative stress

Identifiers

PMID26170730
PMCPMC4492636
OpenAlexW1578285660

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.