Evidence map›Paper›PMID 26168834›Full record

Trial reportChinese medical journal2015

Goal-directed Fluid Therapy May Improve Hemodynamic Stability of Parturient with Hypertensive Disorders of Pregnancy Under Combined Spinal Epidural Anesthesia for Cesarean Delivery and the Well-being of Newborns.

Wei Xiao, Qing-Fang Duan, Wen-Ya Fu, Xin-Zuo Chi, Feng-Ying Wang, Da-Qing Ma, Tian-Long Wang, Lei Zhao

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Chinese medical journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Trial
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Wei Xiao
Qing-Fang Duan
Wen-Ya Fu
Xin-Zuo Chi
Feng-Ying Wang
Da-Qing Ma
Tian-Long WangDepartment of Anesthesiology, Xuan Wu Hospital, Capital Medical University, Beijing 100053, China.
Lei Zhao
Xuan Wu Hospital of the Capital Medical University · CNImperial College London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHypotension induced by combined spinal epidural anesthesia in parturient with hypertensive disorders of pregnancy (HDP) can easily compromise blood supply to vital organs including uteroplacental perfusion and result in fetal distress. The aim of this study was to investigate whether the goal-directed fluid therapy (GDFT) with LiDCO rapid system can improve well-being of both HDP parturient and their babies.

methodsFifty-two stable HDP parturient scheduled for elective cesarean delivery were recruited. After loading with 10 ml/kg lactated Ringer's solution (LR), parturient were randomized to the GDFT and control group. In the GDFT group, individualized fluid therapy was guided by increase in stroke volume (ΔSV) provided via LiDCO rapid system. The control group received the routine fluid therapy. The primary endpoints included maternal hypotension and the doses of vasopressors administered prior to fetal delivery. The secondary endpoints included umbilical blood gas abnormalities and neonatal adverse events.

resultsThe severity of HDP was similar between two groups. The total LR infusion (P < 0.01) and urine output (P < 0.05) were higher in the GDFT group than in the control group. Following twice fluid challenge tests, the systolic blood pressure, mean blood pressure, cardiac output and SV in the GDFT group were significantly higher, and the heart rate was lower than in the control group. The incidence of maternal hypotension and doses of phenylephrine used prior to fetal delivery were significantly higher in the control group than in the GDFT group (P < 0.01). There were no differences in the Apgar scores between two groups. In the control group, the mean values of pH in umbilical artery/vein were remarkably decreased (P < 0.05), and the incidences of neonatal hypercapnia and hypoxemia were statistically increased (P < 0.05) than in the GDFT group.

conclusionsDynamic responsiveness guided fluid therapy with the LiDCO rapid system may provide potential benefits to stable HDP parturient and their babies.

Indexed as

AdultAnesthesia, EpiduralAnesthesia, SpinalBlood PressureCesarean SectionFemaleFluid TherapyHumansHypertension, Pregnancy-InducedInfant, NewbornIsotonic SolutionsPregnancyPregnancy OutcomeRinger's LactateIsotonic SolutionsRinger's Lactate

Identifiers

PMID26168834
PMCPMC4717919
OpenAlexW1163593034

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.