Evidence map›Paper›PMID 26167680›Full record

Trial reportPloS one2015

Improving Patient to Patient CT Value Uniformity with an Individualized Contrast Medium Protocol Tailored to Body Weight and Contrast Medium Concentration in Coronary CT Angiography.

Yan Xing, Gulina Azati, Cun-xue Pan, Jun Dang, Sailendra Jha, Wen-ya Liu

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yan XingDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Gulina AzatiDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Cun-xue PanDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Jun DangDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Sailendra JhaDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Wen-ya LiuDepartment of Radiology, the First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s. For both groups, patients were further divided into four subgroups with different CM concentrations: A1, B1 (300 mg I/ml); A2, B2 (320 mg I/ml); A3, B3 (350 mg I/ml) and A4 and B4 (370 mg I/ml). For each patient, the CT values of the ascending aorta, left ventricle and coronary arteries were measured. One-way analysis of variance was used to compare CT values among subgroups. Among the subgroups of A, sufficient attenuation of greater than 300HU was obtained in all target vessels with no difference among them. Among the subgroups of B, the CT values had significant difference in left ventricle, left circumflex branch, proximal and distal segment of the right coronary artery (all p < 0.05), and the attenuation with 300 mg I/ml CM concentration was significantly lower than that with 370 mg I/ml. Compared with group B, group A used less volume (62.83 ml vs. 80.00 ml, P<0.001) and lower rate (5.21 ml/s vs. 5.50 ml/s, P<0.001) of CM. Compared with the conventional contrast medium injection protocol with fixed volume and injection rate, the individualized-protocol based on patient weight and contrast concentration provides overall contrast dose reduction and achieves more homogenous attenuation among different coronary vessels and patients.

Indexed as

AortographyBody WeightClinical ProtocolsContrast MediaCoronary AngiographyCoronary Artery DiseaseCoronary VesselsFemaleHeart VentriclesHumansMaleMiddle AgedProspective StudiesTomography, X-Ray ComputedContrast Media

Identifiers

PMID26167680
PMCPMC4500390

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked