Evidence map›Paper›PMID 26158099›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2015

Reconstruction of four-dimensional computed tomography lung images by applying spatial and temporal anatomical constraints using a Bayesian model.

Tiancheng He, Zhong Xue, Bin S Teh, Stephen T Wong

Open access · greenAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Tiancheng HeWeill Cornell Medical College , Houston Methodist Research Institute, Department of Systems Medicine and Bioengineering, Houston, Texas 77030, United States.
Zhong XueWeill Cornell Medical College , Houston Methodist Research Institute, Department of Systems Medicine and Bioengineering, Houston, Texas 77030, United States.
Bin S TehWeill Cornell Medical College , Houston Methodist Hospital, Department of Radiation Oncology, Houston, Texas 77030, United States.
Stephen T WongWeill Cornell Medical College , Houston Methodist Research Institute, Department of Systems Medicine and Bioengineering, Houston, Texas 77030, United States.
Cornell University · USHouston Methodist · USMethodist Hospital · US

Funding

Clinical Evaluation of Lung Motion Tracker for Improved Diagnosis and TreatmentR03EB018977 · NIBIB · METHODIST HOSPITAL RESEARCH INSTITUTE · PI XUE, ZHONG · 2015 to 2016
$160k
NIBIB NIH HHS R03 EB018977
6 · The paper itself

Abstract

Current four-dimensional computed tomography (4-D CT) lung image reconstruction methods rely on respiratory gating, such as surrogate, to sort the large number of axial images captured during multiple breathing cycles into serial three-dimensional CT images of different respiratory phases. Such sorting methods may be subject to external surrogate signal noises due to poor reproducibility of breathing cycles. New image-matching-based reconstruction algorithms refine the 4-D CT reconstruction by matching neighboring image slices, and they generally work better for the cine mode of 4-D CT acquisition than the helical mode due to different table positions of axial images in the helical mode. We propose a Bayesian model (BM) based automated 4-D CT lung image reconstruction for helical mode scans. BM allows for applying new spatial and temporal anatomical constraints in the optimization procedure. Using an iterative optimization procedure, each axial image is assigned to a respiratory phase to make sure the anatomical structures are spatially and temporally smooth based on the BM framework. In experiments, we visually and quantitatively compared the results of the proposed BM-based 4-D CT reconstruction with the respiratory surrogate and the normalized cross-correlation based image matching method using both simulated and actual 4-D patient scans. The results indicated that the proposed algorithm yielded more accurate reconstruction and fewer artifacts in the 4-D CT image series.

Indexed as

Bayesian modelchest imagingfour-dimensional computed tomography reconstructionrespiratory motion

Identifiers

PMID26158099
PMCPMC4478724
OpenAlexW1822269381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.