Evidence map›Paper›PMID 26157998›Full record

ArticleNeurophotonics2015

Computer-generated holography enhances voltage dye fluorescence discrimination in adjacent neuronal structures.

Amanda J Foust, Valeria Zampini, Dimitrii Tanese, Eirini Papagiakoumou, Valentina Emiliani

Open access · hybridAbstract read
In one paragraph

Article in Neurophotonics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Light-field deep learning enables high-throughput, scattering-mitigated calcium imaging.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  3. Review
  4. Article
  5. Scanless two-photon voltage imaging.Nature communications · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Genetically Encoded Voltage Indicators.Advances in experimental medicine and biology · 2021
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Advances in two photon scanning and scanless microscopy technologies for functional neural circuit imaging.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Amanda J FoustParis Descartes University , Biomedical and Fundamental Science Faculty, Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, 45, rue des Saints Pères, 75270 Paris Cedex 06, France.
Valeria ZampiniParis Descartes University , Biomedical and Fundamental Science Faculty, Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, 45, rue des Saints Pères, 75270 Paris Cedex 06, France.
Dimitrii TaneseParis Descartes University , Biomedical and Fundamental Science Faculty, Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, 45, rue des Saints Pères, 75270 Paris Cedex 06, France.
Eirini PapagiakoumouParis Descartes University , Biomedical and Fundamental Science Faculty, Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, 45, rue des Saints Pères, 75270 Paris Cedex 06, France ; INSERM , 45, rue des Saints Pères, 75270 Paris Cedex 06, France.
Valentina EmilianiParis Descartes University , Biomedical and Fundamental Science Faculty, Wavefront-Engineering Microscopy Group, Neurophotonics Laboratory, CNRS UMR8250, 45, rue des Saints Pères, 75270 Paris Cedex 06, France.
Centre National de la Recherche Scientifique · FRDélégation Paris 5 · FRInserm · FRUniversité Paris Cité · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Voltage-sensitive fluorescence indicators enable tracking neuronal electrical signals simultaneously in multiple neurons or neuronal subcompartments difficult to access with patch electrodes. However, efficient widefield epifluorescence detection of rapid voltage fluorescence transients necessitates that imaged cells and structures lie sufficiently far from other labeled structures to avoid contamination from out of focal plane and scattered light. We overcame this limitation by exciting dye fluorescence with one-photon computer-generated holography shapes contoured to axons or dendrites of interest, enabling widefield detection of voltage fluorescence with high spatial specificity. By shaping light onto neighboring axons and dendrites, we observed that dendritic back-propagating action potentials were broader and slowly rising compared with axonal action potentials, differences not measured in the same structures illuminated with a large "pseudowidefield" (pWF) spot of the same excitation density. Shaped illumination trials showed reduced baseline fluorescence, higher baseline noise, and fractional fluorescence transient amplitudes two times greater than trials acquired with pWF illumination of the same regions.

Indexed as

action potentialaxoncomputer-generated holographydendritevoltage imaging

Identifiers

PMID26157998
PMCPMC4478842
OpenAlexW2129247634

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.