Evidence map›Paper›PMID 26153387›Full record

ArticleMagnetic resonance in medicine2016

Improved spoiling efficiency in dynamic RF-spoiled imaging by ghost phase modulation and temporal filtering.

Jon-Fredrik Nielsen, Douglas C Noll

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Imperfect spoiling in variable flip angle TMagnetic resonance in medicine · 2021
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jon-Fredrik NielsenDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Douglas C NollDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.

Funding

MRI Parallel Excitation for Neuroimaging ApplicationsR01NS058576 · NINDS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NOLL, DOUGLAS C · 2008 to 2012
$3.0M
MRI Scanner for Functional Brain ImagingS10OD012240 · OD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NOLL, DOUGLAS C · 2012 to 2012
$2.0M
Improved Functional MRI Using Balanced SSFP and Parallel TransmissionR21EB012674 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NIELSEN, JON-FREDRIK · 2011 to 2012
$404k
Toward layer-specific BOLD fMRI in human cortex at 3T using 3D zoomed-EPI and smallip fast-recovery imagingR21EB019653 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NIELSEN, JON-FREDRIK · 2015 to 2016
$401k
NIBIB NIH HHS R21 EB012674NIBIB NIH HHS R21 EB019653NIH HHS S10 OD012240NINDS NIH HHS R01 NS058576
6 · The paper itself

Abstract

purposeRadiofrequency-spoiled steady-state sequences offer rapid data acquisition with T1- or T2*-weighting. The spoiler gradients in these sequences must be large enough to suppress ghost artifacts, and are chosen empirically. However, certain factors such as the need to minimize gradient first moments or acoustic noise can limit the spoiler size and, hence, the ability to suppress ghosts. We present an acquisition and preprocessing strategy for improved spoiling efficiency in conventional and echo-shifted dynamic radiofrequency-spoiled 3D imaging. THEORY AND

methodsBy requiring each time-frame in a dynamic imaging sequence to contain a particular (restricted) number of total radiofrequency shots, the ghost signal can be made to alternate in sign every other frame. The ghost is then suppressed by Fourier transforming along the temporal dimension, and removing the Nyquist frequency in preprocessing (similar to UNFOLD). The method works for both Cartesian and non-Cartesian imaging.

resultsWe demonstrate improved ghost suppression with the proposed approach, for both conventional and echo-shifted spoiled gradient echo imaging in stationary phantoms and in vivo. Cartesian echo-shifted spoiled gradient echo imaging produces two ghosts shifted in opposite directions, both of which are suppressed with our method.

conclusionFor a given spoiler gradient area, the proposed approach substantially suppresses the ghost signal in both conventional and echo-shifted dynamic radiofrequency-spoiled imaging. Magn Reson Med 75:2388-2393, 2016. © 2015 Wiley Periodicals, Inc.

Indexed as

ArtifactsBrainHumansImaging, Three-DimensionalMagnetic Resonance ImagingPhantoms, Imagingdynamic T1-weighted imagingghost artifactsgradient echoRF-spoiling

Identifiers

PMID26153387
PMCPMC4704999

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked