ArticleMagnetic resonance in medicine2016
Improved spoiling efficiency in dynamic RF-spoiled imaging by ghost phase modulation and temporal filtering.
Article in Magnetic resonance in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Accurate actual flip angle imaging (AFI) in the presence of fat.Magnetic resonance in medicine · 2024Article
- Imperfect spoiling in variable flip angle TMagnetic resonance in medicine · 2021Article
- TOPPE: A framework for rapid prototyping of MR pulse sequences.Magnetic resonance in medicine · 2018Article
- Hexagonal gradient scheme with RF spoiling improves spoiling performance for high-flip-angle fast gradient echo imaging.Magnetic resonance in medicine · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
purposeRadiofrequency-spoiled steady-state sequences offer rapid data acquisition with T1- or T2*-weighting. The spoiler gradients in these sequences must be large enough to suppress ghost artifacts, and are chosen empirically. However, certain factors such as the need to minimize gradient first moments or acoustic noise can limit the spoiler size and, hence, the ability to suppress ghosts. We present an acquisition and preprocessing strategy for improved spoiling efficiency in conventional and echo-shifted dynamic radiofrequency-spoiled 3D imaging. THEORY AND
methodsBy requiring each time-frame in a dynamic imaging sequence to contain a particular (restricted) number of total radiofrequency shots, the ghost signal can be made to alternate in sign every other frame. The ghost is then suppressed by Fourier transforming along the temporal dimension, and removing the Nyquist frequency in preprocessing (similar to UNFOLD). The method works for both Cartesian and non-Cartesian imaging.
resultsWe demonstrate improved ghost suppression with the proposed approach, for both conventional and echo-shifted spoiled gradient echo imaging in stationary phantoms and in vivo. Cartesian echo-shifted spoiled gradient echo imaging produces two ghosts shifted in opposite directions, both of which are suppressed with our method.
conclusionFor a given spoiler gradient area, the proposed approach substantially suppresses the ghost signal in both conventional and echo-shifted dynamic radiofrequency-spoiled imaging. Magn Reson Med 75:2388-2393, 2016. © 2015 Wiley Periodicals, Inc.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials