Evidence map›Paper›PMID 26153071›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2015

Initial Stability of Subtrochanteric Oblique Osteotomy in Uncemented Total Hip Arthroplasty: A Preliminary Finite Element Study.

Liangtao Li, Mingyang Yu, Renshi Ma, Dong Zhu, Guishan Gu

Abstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. A Novel Fast Mobile-Window Small Incision Technique for Hip Arthroplasty in the Elderly and Comparison with Conventional Incision.Medical science monitor : international medical journal of experimental and clinical research · 2017
    Article
  3. Theoretical Implications of Periacetabular Osteotomy in Various Dysplastic Acetabular Cartilage Defects as Determined by Finite Element Analysis.Medical science monitor : international medical journal of experimental and clinical research · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Liangtao LiDepartment of Joint Surgery, The First Hospital of Jilin University, Changchun, Jilin, China (mainland).
Mingyang YuDepartment of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, Liaoning, China (mainland).
Renshi MaDepartment of Emergency, The First Hospital of Jilin University, Changchun, Jilin, China (mainland).
Dong ZhuDepartment of Traumatic Orthopaedics, The First Hospital of Jilin University, Changchun, Jilin, China (mainland).
Guishan GuDepartment of Joint Surgery, The First Hospital of Jilin University, Changchun, Jilin, China (mainland).

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSubtrochanteric oblique osteotomy (SOO) has been widely used to reconstruct highly dislocated hips in uncemented total hip arthroplasty. The occurrence of complications can be attributed to the instability of the osteotomy region. The aim of this study was to evaluate the initial stability of SOO in uncemented total hip arthroplasty. MATERIAL AND

methodsA 3-dimensional finite element femur-stem model was created, and a virtual SOO was performed at 4 oblique angles: 30°, 45°, 60°, and 90°. The von Mises stress distribution in the femur-stem complex and the displacement under different oblique angles were evaluated in the SOO models, in comparison with that of the intact model.

resultsThe study demonstrated that the distal fragment of the femur bore more stresses than the proximal fragment, and the maximum stress was concentrated in the femoral neck and the cortical bone, which contacted with the distal end of the stem. SOO increased the stress of both the femur and the stem, and fractures may occur in the stress concentration sites. Additionally, comparing the displacement at different oblique angles, the lateral region was larger than that of the medial region on the subtrochanteric osteotomy plane. The minimum micromotion on the osteotomy plane was obtained when the oblique angle was 45°.

conclusionsThe fit and fill of the distal fragment of the femur and the stem is essential for the stability of the subtrochanteric osteotomy region. The optimal oblique angle for SOO appears to be 45°.