Evidence map›Paper›PMID 26130285›Full record

ArticleInternational orthopaedics2016

Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?

Julio J Jauregui, Qais Naziri, Todd P Pierce, Randa K Elmallah, Jeffrey J Cherian, Ronald E Delanois, Michael A Mont

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Future Prospects for Clinical Applications of Nanocarbons Focusing on Carbon Nanotubes.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Julio J JaureguiCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA.
Qais NaziriDepartment of Orthopaedic Surgery, SUNY Downstate Medical Center, Brooklyn, NY, USA.
Todd P PierceCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA.
Randa K ElmallahCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA.
Jeffrey J CherianCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA.
Ronald E DelanoisCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA.
Michael A MontCenter for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD, 21215, USA. mmont@lifebridgehealth.org.
Sinai Hospital · USSUNY Downstate Health Sciences University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDue to the high number of total hip arthroplasties (THA) revised due to instability, the use of large femoral heads to reduce instability is justifiable. It is critical to determine whether or not large femoral heads used in conjunction with thin polyethylene liners lead to increased wear rates, which can lead to osteolysis. Therefore, by using validated wear-analysis software, we evaluated linear wear rates in a consecutive cohort of patients who underwent primary THA with thin polyethylene liners.

methodsAll patients were selected from a consecutive, prospectively collected database of 241 THAs performed at a single institution by two fellowship-trained joint-reconstruction surgeons between July 2007 and June 2011. These patients were 1:1 matched to a cohort of patients who had conventional-thickness polyethylene liners.

resultsNo significant differences were observed between linear wear rates of thin or conventional-thickness liners. The Kaplan-Meier survivorship for both cohorts was 100 %, and no cases of polyethylene fracture were observed in either cohort.

conclusionsOur results suggest that according to a mean follow-up of 4 years, the use of thin liners in THA is promising. Longer follow-up is required to assess whether these outcomes are observed later.

Indexed as

Hip ProsthesisAgedAged, 80 and overArthroplasty, Replacement, HipCross-Linking ReagentsFemaleFemur HeadFollow-Up StudiesHumansMaleMiddle AgedPolyethyleneProspective StudiesProsthesis DesignProsthesis FailureSurvival AnalysisCross-Linking ReagentsPolyethyleneLarge femoral headsPolyethylene wearProsthetic stabilityRadiographic analysisThin polyethylene linersTotal hip arthroplasty

Identifiers

PMID26130285
OpenAlexW790928594

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.