Evidence map›Paper›PMID 26127058›Full record

ArticleMedical physics2015

Radiation doses in volume-of-interest breast computed tomography--A Monte Carlo simulation study.

Chao-Jen Lai, Yuncheng Zhong, Ying Yi, Tianpeng Wang, Chris C Shaw

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Chao-Jen LaiDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009.
Yuncheng ZhongDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009.
Ying YiDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009.
Tianpeng WangDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009.
Chris C ShawDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009.
The University of Texas MD Anderson Cancer Center · US

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Kathrin Milbury · 1985 to 2026
$290.8M
aSi/CsI FP digital chest imaging with scatter rejectionR01EB000117 · NIBIB · UNIVERSITY OF TEXAS MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2002 to 2005
$2.3M
Optimized Digital Mammography with an a-Se FP ImagerR01CA104759 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2004 to 2007
$2.2M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR33CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2008 to 2010
$1.3M
A Dual Resolution Cone Beam CT System for 3-D Breast ImagingR21CA124585 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI SHAW, CHRIS C · 2007 to 2007
$234k
NCI NIH HHS CA104759NCI NIH HHS CA124585NCI NIH HHS CA13852NCI NIH HHS P30 CA016672NCI NIH HHS P30CA016672NCI NIH HHS R01 CA104759NCI NIH HHS R21 CA124585NCI NIH HHS R33 CA124585NIBIB NIH HHS R01 EB000117
6 · The paper itself

Abstract

purposeCone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region's visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique.

methodsElectron-Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm(2) field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique.

resultsThe ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12.

conclusionsThe authors' Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

Indexed as

Monte Carlo MethodRadiation DosageMammographyPhantoms, ImagingReproducibility of ResultsTomography, X-Ray Computed

Identifiers

PMID26127058
PMCPMC4449356
OpenAlexW1603120194

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.