Evidence map›Paper›PMID 26118300›Full record

ArticleThe British journal of radiology2015

Evaluation of a new system for chest tomosynthesis: aspects of image quality of different protocols determined using an anthropomorphic phantom.

M Jadidi, A Sundin, P Aspelin, M Båth, S Nyrén

Abstract readComparative Study
In one paragraph

Article in The British journal of radiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M Jadidi1 Departments of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.
A Sundin2 Radiology Department, Uppsala University Hospital, Uppsala, Sweden.
P Aspelin4 Departments of Clinical Science, Intervention and Technology, Karolinska University Hospital, Stockholm, Sweden.
M Båth6 Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
S Nyrén8 Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the image quality obtained with the different protocols in a new chest digital tomosynthesis (DTS) system.

methodsA chest phantom was imaged with chest X-ray equipment with DTS. 10 protocols were used, and for each protocol, nine acquisitions were performed. Four observers visually rated the quality of the reconstructed section images according to pre-defined quality criteria in four different classes. The data were analysed with visual grading characteristics (VGC) analysis, using the vendor-recommended protocol [12-s acquisition time, source-to-image distance (SID) 180 cm] as reference, and the area under the VGC curve (AUCVGC) was determined for each protocol and class of criteria.

resultsProtocols with a smaller swing angle resulted in a lower image quality for the classes of criteria "disturbance" and "homogeneity in nodule" but a higher image quality for the class "structure". The class "demarcation" showed little dependency on the swing angle. All protocols but one (6.3 s, SID 130 cm) obtained an AUCVGC significantly <0.5 (indicating lower quality than reference) for at least one class of criteria.

conclusionThe study indicates that the DTS protocol with 6.3 s yields image quality similar to that obtained with the vendor-recommended protocol (12 s) but with the clinically important advantage for patients with respiratory impairment of a shorter acquisition time. ADVANCES IN KNOWLEDGE: The study demonstrates that the image quality may be strongly affected by the choice of protocol and that the vendor-recommended protocol may not be optimal.

Indexed as

HumansPhantoms, ImagingRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedRadiography, ThoracicReproducibility of Results

Identifiers

PMID26118300
PMCPMC4743566

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.