ArticleBiomedical optics express2015
Mapping conduction velocity of early embryonic hearts with a robust fitting algorithm.
Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- In vivo dynamic imaging reveals the oviduct as a leaky peristaltic pump in transporting a preimplantation embryo toward pregnancy.Biomedical optics express · 2025Article
- Emerging trends in the development of flexible optrode arrays for electrophysiology.APL bioengineering · 2023Review
- FRESH 3D bioprinting a contractile heart tube using human stem cell-derived cardiomyocytes.Biofabrication · 2022Article
- Prenatal ethanol exposure impairs the conduction delay at the atrioventricular junction in the looping heart.American journal of physiology. Heart and circulatory physiology · 2021Article
- Thermal effects on cardiac alternans onset and development: A spatiotemporal correlation analysis.Physical review. E · 2021Article
- Optical Electrophysiology in the Developing Heart.Journal of cardiovascular development and disease · 2018Review
- A review of optical pacing with infrared light.Journal of neural engineering · 2018Review
- Volumetric optical mapping in early embryonic hearts using light-sheet microscopy.Biomedical optics express · 2016Article
- Changes in dynamic embryonic heart wall motion in response to outflow tract banding measured using video densitometry.Journal of biomedical optics · 2016Article
- Probing the Electrophysiology of the Developing Heart.Journal of cardiovascular development and disease · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Cardiac conduction maturation is an important and integral component of heart development. Optical mapping with voltage-sensitive dyes allows sensitive measurements of electrophysiological signals over the entire heart. However, accurate measurements of conduction velocity during early cardiac development is typically hindered by low signal-to-noise ratio (SNR) measurements of action potentials. Here, we present a novel image processing approach based on least squares optimizations, which enables high-resolution, low-noise conduction velocity mapping of smaller tubular hearts. First, the action potential trace measured at each pixel is fit to a curve consisting of two cumulative normal distribution functions. Then, the activation time at each pixel is determined based on the fit, and the spatial gradient of activation time is determined with a two-dimensional (2D) linear fit over a square-shaped window. The size of the window is adaptively enlarged until the gradients can be determined within a preset precision. Finally, the conduction velocity is calculated based on the activation time gradient, and further corrected for three-dimensional (3D) geometry that can be obtained by optical coherence tomography (OCT). We validated the approach using published activation potential traces based on computer simulations. We further validated the method by adding artificially generated noise to the signal to simulate various SNR conditions using a curved simulated image (digital phantom) that resembles a tubular heart. This method proved to be robust, even at very low SNR conditions (SNR = 2-5). We also established an empirical equation to estimate the maximum conduction velocity that can be accurately measured under different conditions (e.g. sampling rate, SNR, and pixel size). Finally, we demonstrated high-resolution conduction velocity maps of the quail embryonic heart at a looping stage of development.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.