ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2015
Endovascular treatment of bifurcation intracranial aneurysms with the WEB SL/SLS: 6-month clinical and angiographic results.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 6 syntheses or guidelines pooled it.
- A systematic review of the Woven EndoBridge device-do findings in pre-clinical animal models compare to clinical results?Acta neurochirurgica · 2023Pooled it
- Microsurgical clipping versus newer endovascular techniques in treatment of unruptured anterior communicating artery-complex aneurysms: a meta-analysis and systematic review.Neurosurgical review · 2022Pooled it
- A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2020Pooled it
- Innovation in neurosurgery: less than IDEAL? A systematic review.Acta neurochirurgica · 2017Pooled it
- Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis.AJNR. American journal of neuroradiology · 2016Pooled it
- Endovascular Treatment of Intracranial Aneurysms with the WEB Device: A Systematic Review of Clinical Outcomes.AJNR. American journal of neuroradiology · 2016Pooled it
- Prediction of persistent incomplete occlusion of intracranial aneurysms treated with woven EndoBridge device.Neurosurgical review · 2025Article
- Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score-Matched Analysis.Neurosurgical review · 2024Article
- Treatment of Acutely Ruptured Cerebral Aneurysms With the Woven EndoBridge Device: Experience Post-FDA Approval.Neurosurgery · 2020Article
- Recurrence of endovascularly and microsurgically treated intracranial aneurysms-review of the putative role of aneurysm wall biology.Neurosurgical review · 2019Review
- WEB Treatment of Ruptured Intracranial Aneurysms: A Single-Center Cohort of 100 Patients.AJNR. American journal of neuroradiology · 2017Observational
- Article
- WEB Treatment of Ruptured Intracranial Aneurysms.AJNR. American journal of neuroradiology · 2016Observational
- PulseRider Stent-Assisted Coiling of Wide-Neck Bifurcation Aneurysms: Periprocedural Results in an International Series.AJNR. American journal of neuroradiology · 2016Article
- One-Year Angiographic Follow-Up after WEB-SL Endovascular Treatment of Wide-Neck Bifurcation Intracranial Aneurysms.AJNR. American journal of neuroradiology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe WEB device is a recent intrasaccular flow disruption technique developed for the treatment of wide-necked intracranial aneurysms. To date, a single report on the WEB Single-Layer (SL) treatment of intracranial aneurysms has been published with 1-months' safety results. The aim of this study is to report our experience and 6-month clinical and angiographic follow-up of endovascular treatment of wide-neck aneurysm with the WEB SL.
methodsTen patients with 10 unruptured wide-necked aneurysms were prospectively enrolled in this study. Feasibility, intraoperative and postoperative complications, and outcomes were recorded. Immediate and 6-month clinical and angiographic results were evaluated.
resultsFailure of WEB SL placement occurred in two cases. Eight aneurysms were successfully treated using one WEB SL without additional treatment. Three middle cerebral artery, four anterior communicating artery, and one basilar artery aneurysms were treated. Average dome width was 7.5 mm (range 5.4-10.7 mm), and average neck size was 4.9 mm (range 2.6-6.5 mm). No periprocedural complication was observed, and morbi-mortality at discharge and 6 months was 0.0%. Angiographic follow-up at 6 months demonstrated complete aneurysm occlusion in 2/8 aneurysms, neck remnant in 5/8 aneurysms, and aneurysm remnant in 1/8 aneurysm.
conclusionsFrom this preliminary study, treatment of bifurcation intracranial aneurysms using WEB SL is feasible. WEB SL treatment seems safe at 6 months; however, the rate of neck remnants is not negligible due to compression of the WEB SL. Further technical improvements may be needed in order to ameliorate the occlusion in the WEB SL treatment.